Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions (HxWxD)
Dimensions
Dimensions
Dimensions
(with feet/bezel)
Weight
Weight
Weight
Weight (approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
DA - 12565
Worldwide — Version 13 — March 26, 2007
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Maximum
Minimum
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
BTU/HR
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL385 G2
- Click on: "Power Calculator" link. (You may need to scroll down to see it.)
Rated Steady-State Power 800/850/1000 W
Maximum Peak Power
Operating
Non-operating
101.7° F (38.7° C)
Operating
Non-operating
Idle Minimum (Fixed Disk
Drives Spinning)
L L L L WAd (BELS)
L L L L pAm (dBA)
Operating Minimum
(Random Seeks to Fixed
Disks)
L L L L WAd (BELS)
L L L L pAm (dBA)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
60 lb (27.22 kg)
47.18 lb (20.41 kg)
100-132 VAC, 200-240 VAC
10A (100VAC), 10A (120VAC), 6.1A (200VAC)
50 to 60 Hz
1000/1056/1205 W
3490/3680/4150
800/850/1000 W
50° to 95° F (10° to 35° C) at sea level with an
altitude de-rating of 1.8° F per 1000 ft (1.0° C
per 304.8 m) to 10,000 ft (3048 m) no direct
sunlight allowed. Maximum rate of change is 18°
F/Hr (10° C/Hr). Upper operating limit is 10,000
ft (3,048 m) or 70 Kpa/10.1 psia.
System performance may be reduced if operating
with a fan fault or above 30° C.
-22° to 140° F (-30° to 60° C) Maximum rate of
change is36° F/Hr (20° C/Hr). Upper non-
operating limit is 30,000 ft (9,144 m) or
30.3KPa/4.4 psia.
10% to 90% relative humidity (Rh), 28° C
maximum wet bulb temperature.
5% to 95% relative humidity (Rh), 38.7° C
maximum wet bulb temperature.
6.4
47
6.6
49