Technical Specifications - HP ProLiant DL1000 Quickspecs

Multi node server
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions (H x W x D)
Dimensions
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
DA - 13309
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
3.44 x 17.64 x 28.91 in (8.74 x 44.81 x 73.43 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
NOTE: To review typical system power ratings use the HP Power Advisor
NOTE:
NOTE:
NOTE:
which is available online located at url:
efficient
or
www.hp.com/go/hppoweradvisor
Rated Steady-State Power 653.10W (at 100 VAC),
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (L
Canada — Version 31 — April 8, 2011
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
72.00 lb (32.7 kg)
40.00 lb (18.2 kg)
90 to 140 VAC
180 to 264 VAC
7.31A at 115VAC
3.6A at 230VAC
47 to 63 Hz
855W (at 100 VAC),
840.72W (at 200 VAC)
www.hp.com/go/proliant-energy-
653.08W (at 200 VAC)
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
10% to 85% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
10,000 ft (3050 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
) and declared