Panasonic WJ-MS488 Operating Instructions Manual page 27

Multiple surveillance cameras quad unit
Hide thumbs Also See for WJ-MS488:
Table of Contents

Advertisement

• Connection with the Alarm Output Connector
Power capacity of alarm output connector less than
100 mA:
• Make sure to match the polarity when connect-
ing the buzzer to the alarm output connector.
• Connect the positive pole (+) of the buzzer to
pin 11 of the alarm output connector.
• Remote Control
You can control the SEQUENCE, PLAY, EL-ZOOM, STILL modes, and the MULTISCREEN/QUAD SHIFT, VIDEO
SELECT, and MENU/ESC buttons from a remote controller. Connect ALARM/REMOTE Connector (pin 5) to the ground
terminal. These functions are activated by contact with the ground terminal. The pin assignment is as follows.
Buzzer
Alarm Recover In
Alarm Reset Out
Play back
Alarm Out
Ground
Ground
13
12
11
10
9
25
24
23
22
21
Ground
Still
Sequence
Zoom
Ground
Power capacity of alarm output connector more than
100 mA:
• Connect the buzzer through a relay circuit to pin
11 of the alarm output connector. Do not con-
nect it directly.
+24V
Multiscreen Select
MENU/ESC
ALARM/REMOTE Select
ALARM/REMOTE (CH4)
ALARM/REMOTE (CH3)
ALARM/REMOTE (CH2)
8
7
6
5
4
3
2
20
19
18
17
16
15
14
ALARM/REMOTE (CH5)
ALARM/REMOTE (CH6)
ALARM/REMOTE (CH7)
ALARM/REMOTE (CH8)
-25-
NO
NC
To Buzzer
C
Relay
NC: Normally Closed Contact
NO: Normally Open Contact
C:
Common
ALARM/REMOTE (CH1)
1
Ground

Advertisement

Table of Contents
loading

Table of Contents