WCOM/GSM/WMO2/WMO2ATDOC
4.9.2 DTE-DCE character framing
Application to GSM
GSM to application
Application to GSM
GSM to application
Application to GSM
GSM to application
This command is used to determine the local serial port start-stop
(asynchronous) character framing that the DCE shall use.
Command syntax:
* <format>:
0
Autodetect
1
8 Data 2 Stop
2
8 Data 1 Parity 1 Stop
3
8 Data 1 Stop
4
7 Data 2 Stop
5
7 Data 1 Parity 1 Stop
6
7 Data 1 Stop
* <parity>:
0
Odd
1
Even
2
Mark
3
Space
4
None
Note 1) setting a character framing different from 8N1 will disable
autobauding (in the case it was activated). However setting it back to 8N1
will not re-enable autobaud.
Note 2) setting the framing to 8N1 will let the autobauding enabled, if it
was already enabled (implying framing was already 8N1).
AT+ICF?
+ICF: 3,4
current values
OK
AT+ICF=?
+ICF: (1-6),(0-4)
possible values.
OK
AT+ICF=0,0
OK
new values
WAVECOM confidential ©
+ICF
AT+ICF= <format>, <parity>