GAS REQUIREMENTS

Verify the type of gas supply to be used, either Natural or L.P., and make sure the mark-
ing on the appliance rating plate agrees with that of the supply. The rating plate is lo-
cated on the rear of the grill. An "X" will be marked next to the type of gas that the unit is
orifice for.
L.P. gas installation requires the use of a regulator set for 10"W.C. pressure. Natural gas
installation requires a pressure of 7"W.C.
An installer supplied gas shut-off valve must be installed in an easily accessible location.
All installer supplied parts must conform to local codes, or in the absence of local codes,
with the latest edition of the National Fuel Gas Code, ANSI Z223.1
All pipe sealants must be an approved type and resistant to the actions of L.P. and Natu-
ral gases. Never use pipe sealant on flare fittings. All gas connections should be made
by a competent technician and in accordance with local codes and ordinances. In the ab-
sence of local codes, the installation must comply with the latest edition of the National
Fuel Gas Code, ANSI Z223.1
Gas conversion kits are available from your dealer or ProFire. When ordering have avail-
able the model number, and type of gas (L.P. or Natural) which you need the ProFire grill
orifice for. To convert to LP gas the model # will be GCKLP followed by the model # of
your grill. To convert to Natural gas the model # will be GCKNAT followed by the model
number of your grill.
Total gas consumption of the ProFire Gas Grill with all burners on "HI":
Main Burners 25,000 BTU each Total 50,000 BTU
Side Burner 14,000 BTU
Rear Infrared Burner 12,500 BTU
The appliance and its individual shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2 PSIG (3.5kPa.). This appliance must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 PSIG (3.5kPa.).
The installation of this appliance must conform with local codes or, in the absence of lo-
cal codes, to the latest edition of the National Fuel Gas Code, ANSI Z223.1. Installation in
Canada must be in accordance with the Standard Can1-b149.1 or .2 (installation code for
gas burning appliances and equipment) and local codes.