GAS REQUIREMENTS

Verify the type of gas supply to be used, either Natural or L.P., and make sure the marking on the ap-
pliance rating plate agrees with that of the supply. The rating plate is located on the rear of the grill be-
hind the side burners or on the right side behind the faceplate. An "X" will be marked next to the type
of gas that the unit is orifice for.
L.P. gas installation requires the use of a regulator set for 11"W.C. pressure. Natural gas installation
requires a pressure of 7"W.C.
An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer
supplied parts must conform to local codes, or in the absence of local codes, with the latest edition of
the National Fuel Gas Code, ANSI Z223.1
All pipe sealants must be an approved type and resistant to the actions of L.P. and Natural gases.
Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician
and in accordance with local codes and ordinances. In the absence of local codes, the installation must
comply with the latest edition of the National Fuel Gas Code, ANSI Z223.1
Gas conversion kits are available from your dealer or ProFire. When ordering have available the model
number, and type of gas (L.P. or Natural) which you need the ProFire grill orificed for. To convert to LP
gas the model # will be GCKLP followed by the model # of your grill. To convert to Natural gas the
model # will be GCKNAT followed by the model number of your grill.
MODEL
48G
48S
48R
48RS
27G
27R
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5kPa.). This ap-
pliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 PSIG (3.5kPa.).
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
latest edition of the National Fuel Gas Code, ANSI Z223.1. Installation in Canada must be in accord-
ance with the Standard Can1-b149.1 or .2 (installation code for gas burning appliances and equipment)
and local codes.
TOTAL GAS CONSUMPTION
of the ProFire gas grill with all burners on "HIGH":
BTU
88,000
96,000
101,500
109,500
44,000
57,500
MODEL
36G
36R
40S
40R
SINGLE SIDE BURNER
DOUBLE SIDE BURNER
6
BTU
66,000
79,500
74,000
87,500
15,000
30,000