LOCATION REQUIREMENTS

CLEARANCE TO COMBUSTIBLE CONSTRUCTION
Minimum clearance from sides and back of unit to adjacent combustible construction be-
low top of unit, 12" from sides and back. Minimum horizontal clearance from sides and
back of unit to adjacent vertical combustible construction extending above top of unit
12" from sides and back.
CLEARANCE TO NON-COMBUSTIBLE CONSTRUCTION
It is desirable to allow at least 6" side clearance to non-combustible construction above
the cooking surface for counter space. ProFire gas grills can be placed directly adjacent
to non-combustible construction below the cooking surface.
LOCATION
When determining a suitable location take into account concerns such as exposure to
wind, proximity to traffic paths and keeping any gas supply lines as short as possible.
Locate the grill only in a well-ventilated area. Never locate the grill in a building, garage,
breezeway, shed or other such enclosed areas without an approved ventilation system.
During heavy use, the grill will produce a lot of smoke. Ensure that there is adequate area
for smoke to dissipate.
VENTILATION HOODS
When installing your grill under overhead-unprotected areas the use of a ventilation hood
with a minimum of 600CFM is necessary.