Table of Contents

Advertisement

a p p e n d i x b
E R R O R M E S S A G E S
Display readout
AUTO (Automatic protocol detec-
tion error)
LERR (Lamp error)
MERR (Memory error)
CSER (Check-sum error)
****
ShER (Short error)
Hot (Hot lamp)
FbEP (Feedback error pan)
FbET (Feedback error tilt)
FbER (Feedback error pan/tilt)
PAER (Pan time-out)
TIER (Tilt time-out)
COER (Color wheel time-out)
CYER (Cyan wheel time-out)
MAER (Magenta wheel time-out)
YEER (Yellow wheel time-out)
24
Appears if...
... automatic protocol detection is
enabled and there is no control input.
... the lamp doesn't ignite within 10
minutes of receiving the 'Lamp ON'
command.
... the EEPROM memory cannot be
read.
...a software upload is unsuccessful.
... there is no communication between
the control panel and motherboard.
This appears briefly when switching on
the fixture.
... the fixture detects the lamp is ON
but no 'Lamp ON' command has been
received. This can occur if the lamp
relay is stuck.
... you attempt to strike the lamp within
8 minutes after having switched it off.
The fixture will store the 'Lamp ON'
instruction and strike the lamp once the
8 minutes period has elapsed.
...pan (FbEp), tilt (FbET) or both
(FbER) feedback circuits are malfunc-
tioning.
...the pan or tilt indexing circuit is mal-
functioning.
...the magnetic-indexing circuit mal-
functions or the effect wheel is mis-
aligned.

Error Messages

What to do
• Verify that controller is connected
properly and sending data.
• Check the lamp
• Check voltage and frequency set-
tings
• Contact service technician.
• Reload software, see page 19.
• Check fuses.
• Check cable between control panel
and motherboard.
• Reinstall software.
• Contact service technician.
• The fixture may be operated but
remote lamp on/off may be effected.
• Contact service technician.
• Wait until the lamp strikes.
• The fixture will still operate, though
with reduced maximum speed to pre-
vent the fixture from losing track of its
position.
• Contact service technician.
• After the time-out the fixture will work
normally.
• Contact service technician.
• After the time-out, the effect in ques-
tion stops in a random position.
• Contact service technician.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents