Martin MAC 300 User Manual page 19

Table of Contents

Advertisement

M a i n f u s e
The main fuse holder is built in to the mains input socket. Never replace the fuse with one of a different rating!
Unplug the mains cable from the input socket. Pry open the fuse holder and remove the fuse.
1.
2.
Replace the fuse with one of the same type. The fuse rating is listed on serial number label.
3.
Close the fuse holder and replace the mains cable.
C h a n g i n g t h e X L R p i n - o u t
The signal polarity of the XLR connectors can be reversed,
allowing the fixture to be connected directly to those Martin
devices with reversed polarity (pin 3 -). Optionally, a phase-
reversing cable may be used.
1.
Disconnect the fixture from AC power. Remove the 2
Philips screws from the cover on the arm opposite
the side with the visible motor and pull off the cover.
2.
Position the jumpers on PL 233 and PL 234 for
the desired XLR pin-out as shown.
3.
Replace the cover before applying power.
O p t i m i z i n g r e f l e c t o r a l i g n m e n t
The MAC 300 reflector is aligned at the factory. Due to differences between lamps, however, fine adjustment may
improve performance.
Strike the lamp and shine the light on a flat surface.
1.
2.
See Figure 1. Center the hot-spot (the brightest part of the beam) by turning the 3 adjustment
screws one at a time with a 3 mm Allen wrench. If there is no hot-spot, adjust the reflector until
the light is even.
3.
To reduce a hot-spot, "push" the reflector out by turning all 3 screws counterclockwise 1/4-turn at
a time until the light is evenly distributed.
4.
If the light is brighter around the edge than it is in the center, or if light output is low, the lamp is
too far back in the reflector. "Pull" the reflector in by turning the screws clockwise 1/4-turn at a
time until the light is bright and evenly distributed.
U p d a t i n g s o f t w a r e
The latest CPU control software for the MAC 300 is available from your Martin dealer and the Martin web site. This
software is uploaded to the MAC 300 using the Martin MPBB1 Uploader. The display module and feedback system
software are not updated this way.
N o r m a l u p l o a d
Update software is uploaded using a Martin uploader such as the MPBB1. The uploader is connected to the fixture just
like a controller. Under normal conditions, software can be installed from a remote location - there is no need to set the
MAC 300 to boot mode. Please refer to the uploader manual for further instructions.
B o o t m o d e u p l o a d
If the data is corrupted during transmission, a check-sum error (
switches to boot mode (
If a software upload is interrupted, the fixture must be turned off for at least 10 seconds before a new upload can be
attempted. When powered on, a check-sum error occurs and the fixture goes into boot mode, ready for a second upload
attempt. Select boot mode upload on the uploader.
If there is no functional software in memory, the fixture must be set to boot mode manually. If the control panel works,
UP Ld
select
U PLd
) and is ready for a boot mode upload as described in the uploader manual.
U TIL
from the
menu and confirm when
Martin pin-out
CS ER
S URE
is displayed by pressing [ENTER].
Basic Service
PL234
PL233
DMX pin-out
(default)
Figure 7: XLR jumpers
) occurs and after 15 seconds the fixture
PL234
PL233
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents