Technical Data - AGA FFD Owner's Manual

Gas hob
Hide thumbs Also See for FFD:
Table of Contents

Advertisement

HOTPLATE
NATURAL GAS G20 - (APPLIANCE CATEGORY I
BURNER TYPE
MAXIMUM HEAT
INPUT
INJECTOR MARKING
PRESSURE POINT POSITION: REAR LH SIDE OF APPLIANCE AT HOTPLATE LEVEL
PRESSURE SETTING:
BURNER IGNITION: H.T. SPARK
PROPANE G31 - (APPLIANCE CATEGORY I
BURNER TYPE
MAXIMUM HEAT
INPUT
INJECTOR MARKING
PRESSURE POINT POSITION: REAR LH SIDE OF APPLIANCE AT HOTPLATE LEVEL
PRESSURE SETTING:
BURNER IGNITION: H.T. SPARK
ELECTRIC GRILL AND OVENS
GRILL ELEMENT - POWER RATING 2 x 0.95 kW
TOP OVEN - POWER RATING 1.4kW
LOWER OVEN (FANNED) - 1.75kW

TECHNICAL DATA

R.H.F.
L.H.R.
ULTRA-RAPID RAPID
3.5 kW
3.0 kW
130
116
20mbar
3+
R.H.F.
L.H.R.
ULTRA-RAPID RAPID
3.5 kW
3.0 kW
(250g/h)
(214g/h)
(0.50 l/h)
(0.42 l/h)
95
85
G30: 28-30 mbar
5
)
2H
R.H.R.
SEMI-RAPID
1.75 kW
097
)
R.H.R.
SEMI-RAPID
1.75 kW
(125g/h)
(0.25 l/h)
65
G31 - 37 mbar
L.H.F.
SEMI-RAPID
1.75 kW
097
L.H.F.
SEMI-RAPID
1.75 kW
(125g/h)
(0.25 l/h)
65