Pressure Testing - AGA FFD Owner's Manual

Gas hob
Hide thumbs Also See for FFD:
Table of Contents

Advertisement

PRESSURE TESTING

The pressure test point is situated at the rear left hand side of the appliance just below hotplate
level.
Remove screw from pressure test nipple. Fit the pressure gauge onto the pressure test nipple.
Place one of the burner heads and burner cap into position on the hotplate. Light this burner by
pushing in the appropriate control knob, and turning it anti-clockwise to the full on position.
For Natural Gas appliance, the pressure should be 20mbar (8 inches water gauge).
For LPG appliance the pressure should be Propane 37mbar and Butane 28-30mbar.
Turn off the tap, disconnect the pressure gauge and refit pressure test screw to pressure test
nipple.
Check for gas soundness.
10