KitchenAid KDRS807SSS04 Installation Instructions Manual page 8

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance
with CSA Standard O22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON Mgw 1R3 CANADA.
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating*
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
7.8 - 12.5 KW
40 or 59**
16.6 - 22.5 KW
12.6 - 18.5 KW
50
*The NEC calculated load is less than the total connected
load
listed on the model/serial
rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8 '' (34.93 mm) diameter connection
opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a OSA international
Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle.
Be sure the wall receptacle is within reach of
range's final location.
@
Do not use an extension cord.
Explosion Hazard
Use a new CSA International
approved gas supply line.
Install a shut-off
valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturers
instructions.
Type of Gas
Natural gas:
This range is design-certified
by CSA international for use with
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. See "Gas
Conversions"
section. The model/serial
rating plate located
on the right side oven door trim has information on the types
of gas that can be used. if the types of gas listed do not
include the type of gas available, check with the local gas
supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See "Gas
Conversions"
section.
Gas Supply Line
Provide a gas supply line of %" (1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may result
in insufficient gas supply. Pipe-joint compounds
that resist
the action of LP gas must be used. Do not use TEFLON ®t
tape. With LP gas, piping or tubing size can be _/Z' (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.