KitchenAid KDRS807SSS04 Installation Instructions Manual page 16

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

2. Connect the bare ground wire to the range using the ground-
2. Inserttheother2wires(linesland2)undertheother2screw
link screw and cup washer. The ground wire must be
clamps.
attached first and must not contact any other terminal.
0
A. Bare wire from power
supply cable
B. Line 1
C. Hex washer head screw
D, Silver-colored
terminal
block screw
E Line 2
F. Neutral (white) wire
G. UL listed conduit
connector and power
supply cable
3. Loosen (do not remove) the hex washer head screw and
insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.
4. Insert the other 2 wires (lines 1 and 2) under the other 2 screw
clamps.
-\x
__
A. Insert wire under screw clamp.
B. Hex washer head screw
5. Securely tighten the hex washer head screws to
35 Ibs-in. (4.0 N-m) minimum torque to make proper
electrical connection.
6. Tighten the locking ring of the conduit connector.
7. Replace the terminal block cover with screw.
3-wire connection:
Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Loosen (do not remove) the hex washer head screws and
insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.
A. Insert wire under screw clamp.
B. Hex washer head screw
3. Securely tighten the hex washer head screws to
35 Ibs-in. (4.0 N-m) minimum torque to make a proper
electrical connection.
4. Tighten the locking ring of the conduit connector.
5. Replace the terminal block cover with screw.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion,
or fire.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections
may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound
made for use with LP gas to all
pipe thread connections.
B
G
A. Line 1
B, Ground-link
C. Flex washer head screw
D. Silver-colored
terminal
block screw
E Neutral (white) wire
F. Line 2
G. UL listed conduit
connector and power
supply cable
16