Download Print this page

Countertop Preparation; Product Dimensions - KitchenAid YKESC307HS6 Installation Instructions

30" slide-in electric range with self-cleaning thermall/convection oven

Advertisement

Cabinet opening dimensions
25" (63.5 cm) countertop
24" (61 cm) base ..
I
_
I
clearance
to the top
J
30" (76.2 cm) rain.
of the cooktop,
see
_
__
cabinet
opening
width
J. ***
I
1/2" (1.3 cm)
radius
both
18" (45.7 cm)
(67.6 cm)
upper cabinet
opening
depth
to countertop
I
I
4" (10.2 cm) rain.
clearance
to side wall J
\
or other combustible
material
-- both sides
of range.
Important:
Observe
all governing
codes
and ordinances,
Earthed-grounded
electrical outlet is
required.
Cabinet opening
dimensions
that are
shown must be used.
7/8" (2.2 cm)
_. -_min. required
between
cutout
and
cabinet
door
or hinge.
30=3/8" (77.2 cm)
width
36" (91.4 cm)
countertop
height
Countertop
preparation
The cooktop sides of the slide-in range fit
over the cutout edge of your countertop.
If you have a square finish (flat)
countertop
and the opening
width is 30-
3/8" (77.2 cm), no countertop preparation
is required,
Formed front-edged
countertops
must
have molded edge shaved flat 1/4" (0,64
cm) from each front corner of opening,
Tile countertops
may need trim cut back
1/4" (0,64 cm) from each front corner
and/or rounded edge flattened.
width
Earthed outlet -
8" (20.3 cm) to
22" (65.9 cm) from
either
cabinet,
7" (!7.8 cm) max.
from floor.
Do Not pinch the
power supply
cord
between
the range
and the wall.
Do Not seal range
to side cabinets.
64 cm)
30-7/8"
(76.4 cm)
,_/J
Formed
or tiled countertop
trimmed
1/4" (0.64 cm)
back at front corners
of
countertop
opening.
***
Note: 24" (61 cm) min. when bottom
of wood or metal cabinet
is protected
by not less than 1/4" (0.64 cm) flame
retardant
millboard
covered
with not
less than No. 28 MSG sheet steel,
0.016" (0.4 ram) stainless
steel, 0.024"
(0.6 ram) aluminum
or 0.020" (0.5
ram) copper.
30" (76.2 cm) min. clearance
between
the top of the cooking
platform and
the bottom
of an unprotected
wood
or metal cabinet.
If countertop opening width is greater
than 30-3/8" (77.2 cm), adjust the 1/4"
(0.64 cm) dimension.
Countertop
must be level. Place level on
countertop, first side to side; then front to
back. If countertop is not level, range will
not be level. Oven must be level for
satisfactory baking conditions.
22-6/8"
(67.6cm)
cooktop
depth_
Cooktop
sides
of range fit
over edges of
countertop
opening.
Product dimensions
30-7/8"
(76.4 cm)
1-!/2"
cooktop
(3.8 cm)
width
(2.5
cm)
36
'_
(9! .4 cm)
countertop
height
26-3/4"
(65.4 cm)
depth
handle
30" (76.2 cm)
width
When installed in a 24" (61 cm)
base cabinet
with 25" (63.6 cm)
countertop
-- front of oven door
protrudes 1-7/8" (4.8 cm) beyond
base cabinet.
Before you start...
Read electrical and carpentry
instructions.
Proper installation is your responsibility, A
qualified technician must install this range.
Make sure you have everything necessary
for correct installation, It is the customer's
responsibility to make sure that the
countertop has been properly prepared and
that the installation clearances specified on
the model/serial rating plate are met. The
model/serial rating plate is located on the
frame behind the drawer,
Check location where range will be
installed. The range should be located for
convenient use in the kitchen, Recessed
installations must provide complete
enclosure of the sides and rear of range,
ALL OPENINGS IN THE WALL OR FLOOR
WHERE RANGE IS TO BE INSTALLED
MUST BE SEALED.
Cutout shown is for a 25-inch (63,5 cm)
countertop with a 24-inch (61 cm) base
cabinet and no backsplash. If countertop has
a backsplash, see "Countertop preparation,"
Cabinet construction:
This appliance is
designed for use in a base cabinet with a
depth of 24 inches (61 cm). The maximum
depth for overhead cabinets is 13 inches
(33 cm). For the minimum vertical clearance
between the cooking surface and the
overhead cabinets, see Note,*** Overhead
cabinets installed at either side of the
appliance must be a minimum of 18 inches
(45,7 cm) above the cooking surface, The
minimum horizontal distance between the
overhead cabinets is 30 inches (76,2 cm).
Injury Hazard
To eliminate the risk of burns or fire,
avoid installing cabinet storage above
the cooking surface. If cabinets are
already installed, reduce the hazard of
reaching over a heated cooking surface
by installing a range hood.The range
hood should extend a minimum of 5
inches out from the bottom front of the
cabinets.
Reaching over a heated cooking
surface could result in a serious burn
or other personal injury.
Note: The metal chassis of the range MUST
be earth-grounded in order for the control
panel to work, If the metal chassis of the
range is not earth-grounded, NO keypads will
operate. Check with a qualified electrician if
you are in doubt as to whether the metal
chassis of range is earth-grounded.
Mobile
home installation
The installation of this range must conform to
the Manufactured Home Construction and
Safety Standards, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD,
Part 280); or when such standard is not
applicable, the Standard for Manufactured
Homes Installations (Manufactured Home
Sites, Communities and Setups), ANSI
A225.1/NFPA 501A, or with local codes*.
In Canada, the installation of this range must
conform with the current standards
CAN/CSA-Z 240 -- latest edition**, or with
local codes.
When this range is installed in a mobile home,
it must be secured to the floor during transit.
Any method of securing the range is
adequate as long as it conforms to the
standards listed above.
Four-wire power supply cord must be used in
a mobile home installation. The appliance
wiring will need to be revised.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch
Park
Quincy, Massachusetts
02269
** Canadian
Standard
Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario
Mgw 1 R3
Panel A

Advertisement

loading

This manual is also suitable for:

Ykesc300hw6Ykerc607hp5Ykerc607hp6Ykerc607hb6Ykerc607hs5Ykesc307ht6 ... Show all