Whirlpool CET8000AQ1 Installation Instructions Manual page 10

Commercial stacked washer/dryer gas or electric
Table of Contents

Advertisement

Available languages

Available languages

STACKED
WASHER/GAS
DRYER
INSTALLATION
REQUIREMENTS
Stacked
Washer/Gas
Dryer
Gas
Supply
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized
service personnel.
FaUure to do so can result in death, explosion, or fire.
IMPORTANT:
Observe all governing codes and ordinances.
This installation must conform with all local codes and
ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSi Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park, Quincy, MA 02269
CSA international
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this washer/dryer
has been certified by CSA
International for use at altitudes up to 10,000 feet (3048 m)
above sea level at the B.T.U. rating indicated on the model/
serial plate. Burner input adjustments
are not required when
the washer/dryer
is operated up to this elevation.
When installed above 10,000 feet (3048 m), a four percent
(4%) reduction of the burner B.T.U. rating shown on the model/
serial plate is required for each 1,000 foot (305 m) increase in
elevation. For assistance when converting to other gas types
and/or installing above 10,000 feet (3048 m) elevation, contact
your local service company.
10