Download Print this page

Conversion To Different Gas Type - Fisher & Paykel GC36 Installation Instructions Manual

Hide thumbs Also See for GC36:

Advertisement

Available languages

Available languages

Installation
Instructions
Conversion
to different
gas type
Burners can be used with NG or LPG,
provided that the injector orifices appropriate
for the gas delivered are installed.
To change the injector orifices, you will need
a 9/s2"(7mrn) box spanner.
1
Turn off the main electrical supply.
Electrical Shock Hazard inside,
2
Ensure all gas valves are turned off.
3
Remove all grates and burner parts.
4
Unscrew the orifices and replace them
with the correct ones. (size numbers are
stamped on the side, e.g.. 70= 0.70rnrn)
(see fig. 1).
5
Remove the 2 screws holding eacn burner
_)ovs 3 on _ne WOKburner,.
6
Lift hob _rayfrom the proauc_.
Cut Hazard - sharp edges.
7
Reolace me WOK orifice with the correct
one using a 13/32"(10mm)ring spanner
8
Resettirg me Venturi (see fig. 2):
E _
JViththe Product isolated from tie electrica
supply, ignite the burner using a ma_cn.
The flame wi
sroDaDly be lifting offthe
burner see fig. 3).
_ Loosen me venturl securing screw. Move
me venturi towards the injector unti _ne
flame begins to 'yellow riD' (seefig. 4).
£ove the venturi back until _neyeuow
riD'just disappears lsee fig. 5) - this is the
zorrect venturi setting. Tighten me securing
screw.
9
To re-fit the GC9 2M "/ODTray,repea_ s_eps
S&6 in reverse.
10 IMPORTANT! Reset the minimum setting
(see Minimum setting or turn down).
11 After re-assembly verify the insulation
resistance and earth continuity of the
electrical circuit.
Continued...
12 The label supplied with the orifices should
be placed over the existing gas type label
to indicate the change.
figure 1
figure 2
lifting off
figure
figure 4
good flame
00
figure 5

Advertisement

loading

This manual is also suitable for:

Gc912Gc912m