Installation
Instructions
Minimum
Clearance
Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
m PREPARING FOR INSTALLATION
OF NEW APPLIANCE
DISCONNECTING
GAS
TURN G AS
SHUT-OFFVALVE
IC?_
DISCONNECTANDDISCARDOLD
_-/_
TO THE OFF
_-_
FLEXIBLE
GAS CONNECTOR
AND
POS,T,ON OLDTRANS,T,ONDUCT,NG
MATERIAL.
REPLACE
WITH NEW
CSA(AGA)
APPROVED
FLEXIBLE
GAS LINE CONNECTOR
AND UL
APPROVED
TRANSITION
DUCT.
WARNING
- NEVER REUSE OLD
FLEXIBLE CONN ECTORS.
The use of old flexible connectors can cause leaks
and personal injury. Always use new flexible connec-
tors when installing gas appliances.
REMOVING LINT FROM WALL
EXHAUST OPENING
, Remove and discard existing plastic or metal foil
transition
duct and replace with UL listed transition
duct.
WALL
INTERNAL DUCT
CHECK T HAT EXHAUST
OPENING
)PENS
ANDCLOSES FREELY.
TILT THE APPLIANCE
SIDEWAYS AND REMOVE
THE FOAM SHIPPING PADS
BY PULLING ATTHE SIDES
AND BREAKING THEM
AWAY FROM THE APPLIANCE
LEGS. BE SURE TO REMOVE
ALL OF THE FOAM PIECES
AROUND THE LEGS.
After the machine is in the home,
remove remaining packing material/
carton from washer.
DO NOT REMOVE SHIPPING ROD AT
THISTIME.
Removestyrofoam block.
Removethe bag containing the
Washer hoses and parts parts from
tub. Put styrofoam block back in tub
II
SturofoamBlock
ilw
opening to hold tub in place during the
rest of installation.
iVlovewasher close to final
position. Make sure there is at least
a 24" clearance on right side of
washer to remove shipping bar. PULL
SHIPPING BAROUT USINGYELLOW
PLASTIC HANDLE.Keep bar so it can
"
Plastic
/
Handle
be reinstalled if washer is ever moved
again.
NEW HONE OR REMODELING FAUCETS/
DRAI N STAN DPIPE/ELECTRICAL LOCATION
Right side of
Unitized Washer/
Dryer.
12"-_
_ ..................
_|
Locate spigots,
"
drain standpipe
s3"
|
and electrical plug
|
!
in this area
!
FLOOR
[] GAS REQUIREMENTS
WARNING
, Installation must conform to local codes and
ordinances, or in their absence, the NATIONAL
FUEL GAS CODE,ANSI Z223.
• This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using
conversion kit WE2SH73 for 24" Models or
WE25H74 for 27" Models, your local service
organization can convert this dryer for use with
propane (LP}gas. ALL CONVERSIONSMUST BE
MADE BYPROPERLY TRAINED AND QUALIFIED
PERSONNELAND IN ACCORDANCEWITH LOCAL
CODESAND ORDINANCE REQUIREMENTS.
• Theappliance must be disconnected from the gas supply
piping system during any pressure testing of that system
at a test pressurein excessof 0.5PSI(3.4KPa}.
• The appliance must be isolated from the gas supply
piping system by closing the equipment shut-offvalve
during any pressure testing of the gas supply piping of
test pressure ecual to or less than 0.5 PSI(3.4 KPa).
27" GAS SUPPLY CONNECTION
3"
Note: 24" Gas supply
connection
has a flexible
hose thus dimensions
will vary.
4