Installation
[-4] LEAK TEST
ILWARNING: NEVER USE ANOPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GAS VALVE.
Check oll connections
for leaks with soopy solution or equivalent.
Apply soop solution. Leak test solution
must not contain
ammo-
nia which could cause damage to the brass fittings.
If leoks ore
found, close valve, retighten the joint, ond repeat the soap test.
[_[] ELECTRICAL CONNECTION
INFORMATION
WARNING
- TOREDUCE T HE
RISK OF FIRE, ELECTRICAL SHOCK,
AND PERSONAL INJURY:
, DO NOT USEAN EXTENSIONCORD ORAN ADAPTER
PLUGWITH THiS APPLIANCE.
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
ELECTRICAL CODE,ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time-
delay fuse. If electrical supply provided does not meet the
above specifications, it is recommended that a licensed
electrician install an approved outlet.
WARNING
- THIS DRYER IS
EQUIPPED
A THREE-PRONG
(GROUNDING)
PLUG FOR YOUR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD
BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE-PRONG
RECEPTACLE. DO NOT CUT
OR REMOVE
THE GROUNDING
PRONG
FROM
THIS PLUG.
Instructions
ENSURE PROPER GROUND EXISTS BEFORE USE.
GROUNDING
INSTRUCTIONS
This appliance must be grounded. In the event of mal-
function or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
of electric current. This appliance is equipped with a
cord having an equipment-grounding
conductor and a
grounding plug. The plug must be plugged into an ap-
propriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
, WARNING
-Improper
connection
of
the equipment-grounding
conductor can
result
in a
risk of electric shock. Check with a qualified
electri-
cian or serviceman if you are in doubt as to whether
the appliance is properly grounded.
Do not modify the plug provided with the appliance. If it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
[_] EXHAUST
INFORMATION
WARNING
-IN
CANADA AND IN THE
UNITED STATES,THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 IN {102ram). DO NOT USE DUCT
LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE.
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect
installation are not covered by the warranty.
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLEduct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall
cap), and all conditions noted below. The maximum duct
length for rigid metal duct is shown in the table below.