Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
PREPARING FOR INSTALLATION
1
OF NEW APPLIANCE
DISCONNECTING GAS
TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.
WARNING -
FLEXIBLE CONNECTORS.
The use of old flexible connectors can cause leaks and
personal injury. Always use new flexible connectors
when installing gas appliances.
REMOVING LINT FROM WALL
EXHAUST OPENING
• Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
INTERNAL DUCT
OPENING
After the machine is in the home,
remove remaining packing material/
carton from washer.
DO NOT REMOVE SHIPPING ROD AT
THIS TIME.
Remove styrofoam block.
Remove the bag containing the
Washer hoses and parts parts from
tub. Put styrofoam block back in tub
opening to hold tub in place during the
rest of installation.
Move washer close to final
position. Make sure there is at least
a 24" clearance on right side of
washer to remove shipping bar. PULL
SHIPPING BAR OUT USING YELLOW
PLASTIC HANDLE. Keep bar so it can
be reinstalled if washer is ever moved
again.
Installation Instructions
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
NEVER REUSE OLD
WALL
CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
TILT THE APPLIANCE
SIDEWAYS AND REMOVE
THE FOAM SHIPPING PADS
BY PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE APPLIANCE
LEGS. BE SURE TO REMOVE
ALL OF THE FOAM PIECES
AROUND THE LEGS.
NEW HOME OR REMODELING FAUCETS/
DRAIN STANDPIPE/ELECTRICAL LOCATION
Locate spigots,
drain standpipe
and electrical plug
in this area

GAS REQUIREMENTS

2
WARNING
• Installation must conform to local codes and
ordinances, or in their absence, the NATIONAL FUEL
GAS CODE, ANSI Z223.
• This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using
conversion kit WE25X0217, your local service
organization can convert this dryer for use with
propane (LP) gas. ALL CONVERSIONS MUST BE MADE BY
PROPERLY TRAINED AND QUALIFIED PERSONNEL AND
IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE
REQUIREMENTS.
• The appliance must be disconnected from the gas supply
piping system during any pressure testing of that system at a
test pressure in excess of 0.5 PSI (3.4 KPa).
• The appliance must be isolated from the gas supply piping
system by closing the equipment shut-off valve during any
pressure testing of the gas supply piping of test pressure
equal to or less than 0.5 PSI (3.4 KPa).
27" GAS SUPPLY CONNECTION
3"
Note: 24" Gas supply connection has a flexible
hose thus dimensions will vary.
4
Right side of
Unitized Washer/
Dryer.
12"
42"
33"
FLOOR
3"