Step 5, Connect Ductwork; Step 6, Connect Electrical - GE Monogram ZV750 Installation Instructions Manual

36" vent hood
Hide thumbs Also See for Monogram ZV750:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
INSTALLATION -VENTED
TO THE OUTSIDE
CONNECT DUCTWORK
• Remove shipping tape from the damper.
• Install ductwork,
making connections
in the direction of airflow as illustrated.
• Push duct over the exhaust outlet and damper.
Airflow
Duct tape over
seam and
screw
--
Screw
-ACAUTION:
Do not use sheet metal
screws at the exhaust outlet connection.
Doing
so will prevent proper dumper
operation.
Seal
connection
with tape onlg.
• Secure joints in ductwork
with sheet metal screws.
• Wrap all duct joints and the flange connections
with aluminized
duct tape for an airtight
seal.
_-1 CONNECT ELECTRICAL
Verify that power is turned
off at the source.
-_WAR N ING:_f h ouse
wiring
isnot 2 -wire
with u ground wire, u ground must be provided
bg the installer. When house wiring is aluminum,
be sure to use U.L.-upproved untioxidant
compound
and aluminum-to-copper
connectors.
• Remove the junction
box cover and the selected
knockout.
boxcover
• Secure the house wiring to the junction
box with
a strain relief (not provided).
• Connect the white lead to the branch circuit white lead.
• Connect the black lead to the branch circuit black lead.
• Connect the green/gellow
lead to the branch
circuit green lead or bare ground lead.
• Secure all the connections
with wire nuts on each
electrical connector.
• Push the wires into the junction
box and replace
the cover. Be sure the wires are not pinched.
• Secure the junction
box cover with the 2 original
screws.
12