Download Print this page

GE Monogram ZV750 Installation Instructions Manual page 4

36" vent hood
Hide thumbs Also See for Monogram ZV750:

Advertisement

Design Information
36" Vent Hood
Advance
Plannin
Using Duct Cover Accessories
• A duct cover accesso_ y may be required
for
your hood installation
height. Refer to this
chart to determine
the need for the ZX10SY
accessoiy.
ZV750SYDuct CoverDimensions
Hood and
Accessory
A
B
ZX750SY
18-7/8"
22-13/16"
ZX10SY
-
34-1/4"
9-!!
11-7/8"
/4"
,
Ductwork
• Determine
the exact location
of the vent hood.
• Plan the route
for venting
exhaust
to the
outdoors.
• Use the shortest
and straightest
duct route
possible.
For satisfactory
performance,
duct run
should
not exceed
100 feet equivalent
length
for
any duct configurations.
• Refer to "Duct
Fittings"
chart
to compute
the
maximum
permissable
length
for duct runs to the
outdoors.
Install
a wall cap with damper
or roof cap at the
exterior
opening.
ZV750SYInstallationHeights
Actual
Ceiling
* PossibleHood
Heitlht InstallationHeight
7' 11"
24-1/2"
8'O"
25-I/2"
8'1"
25-1/2" to26-1/2"
8'2"
25-1/2" to27-1/2"
8' 3"
25-1/2" to28-1/2"
8' 4"
25-1/2" to29-1/2"
8'5"
25-1/2"to 30"
8'6"
25-1/2"to 30"
8' 7"
25-I/2" to30"
8'8"
25-1/2"to 30"
8'9"
25-1/2"to 30"
8' 10"
25-1/2" to30"
8' 11"
25-I/2" to 30"
9' O"
25-1/2" to 30"
9' 1"
25-1/2" to 30"
9' 2"
25-1/2" to 30"
9' 3"
25-1/2" to 30"
9' 4"
25-1/2" to 30"
9' 5"
25-1/2" to 30"
9' 6"
25-1/2" to 30"
9' 7"
25-1/2" to 30"
9' 8"
25-1/2" to 30"
9' 9"
25-1/2" to 30"
9' 10"
25-1/2" to 30"
9' 11"
25-1/2" to 30"
10'0"
25-1/2"to30"
Duct Cover
t_
LU
...J
CL
CL
03
>-
O3
0
X
N
>-
fr-
o
Q3
Q3
LU
rj
¢,3
<
* Based on 36" countertop height.
Electrical
Supply
Warning, for
Personal Safety:
Remove house time or open
circuit breaker before beginning
installation.
Do not use an extension
cord or adapter
plug with this appliance.
Follow National
Elecuical
Code or prevailing
local codes
and ordinances.
• Gonnect
the wiring to the house wiring in
accordance
with local codes.
Grounding
Instruction
The giounding
conductor
must
be connected
to
a ground
metal,
permanent
wiring
system,
or an
equipment-grounding
terminal
or lead on the
hood.
Electrical
supply
This vent hood
must
be supplied
with 120V,
60Hz.,
and connected
to an individual,
properly
grounded
branch
circuit,
protected
by a 15 or 20
ampere
circuit
breaker
or time delay fllse.
• Wiring
must be 2 wire with ground.
• If the electrical
supply
does not meet
the
above
requirements,
call a licensed
elecuician
before
proceeding.
• Route
wiring
as close to the installation
location
as possible,
in the ceiling
or soffit.
Warning: The improper
connection
of the equipment-
grounding
conductor
can result in
a risk of electric shock. Check with
a qualified electrician
or service
representative
if you are in doubt whether
the appliance
is properly
grounded.