Combustion Air Supply; Direct/Sidewall Venting Application - Beckett AFII85 Installation Manual

Oil burner afii series types 'hlx' & 'fbx' air tube combinations voltage: 120 volts ac/60 hz
Table of Contents

Advertisement

Inspect/Prepare
|nstal|ation
Site
Figure
1. Burner
label location
General m odel
Informat
on
Seria number,
incuding
date code
and fJel ail
Model
AFII
Seres OI Burner
SERAL
NUMBER
000405 62756
[lllHllll[llll]llllil[l
01L I_URNER
NO P I00001
MFR'S SETTINGS
_TC:
STC _LT:
NOZZI;:
P_MP PRS:
BJBS001R00
000405-62756
4 _ TES ÷ SPEC
s U_TEST S PEC
6 ULTEST S PEC
7 ULTEST S PEC
a _ T_S _ SPEC
'---
R,W. Beckett
m0nufocturer's
settings
.........R.W. Beckett spec[fieot}on
number and revision
'--Can
be custamized by
ind;v dual specification
State and local approvals
• Inspect
Chimney
or Direct
Vent System
Inspect the chimney or vent. Make sure it is properly
sized and in good working condition. Follow the in-
structions supplied by the appliance manufacturer.
• Combustion
Air Supply
Information
Adequate
Combustion
and Ventilation
Air Supply
Required
Failure
to provide
adequate
air supply
could se-
riously
affect the burner
performance
and result
in damage
to the equipment,
asphyxiation,
ex-
plosion
or fire hazards.
The burner cannot properly burn the fuel if it is not
supplied with a reliable combustion air source.
Follow the guidelines in the latest editions of the
NFPA 31 and CSA-B139 regarding providing ad-
equate air for combustion and ventilation.
See NFPA Standard 31 for complete details.
Appliances
located
in confined
spaces:
All
confined spaces should have two (2) permanent
openings; one near the top of the enclosure and
one near the bottom of the enclosure. Each open-
ing must have a free area of not less than one (1)
square inch per 1,000 BTU's per hour of the total
input rating of all appliances within the enclosure.
The openings should have free access to the build-
ing interior, which should have adequate infiltration
from the outside.
Exhaust
fans and other air=using devices:
Size
air openings
large enough to supply all air-using
devices in addition to the minimum size required
for combustion air. If there is any possibility of the
equipment
room developing
a negative pressure
due to exhaust fans, clothes dryers, etc., either
pipe combustion air directly to the burner or provide
a sealed enclosure for the burner and supply it with
its own combustion air supply.
Page 6
Figure
2. Outside
Air Connection
4 inch Duct
--,
\\
\\
\
Air
Inlet
Elbow
/
/'
/
Yi
Inlet Ring
1/4"
Mesh
Screen
SK8810
Direct/Sidewall
Venting
Application
When sidewall venting appliances, carefully follow
appliance and power venter instructions for instal-
lation and wiring.
AFII burners are equipped with a removable air in-
let to allow use of a 4" duct to supply outside air
for combustion.
Do not exceed 70 equivalent feet.
Allow 6 feet for each elbow.
1. Remove the inlet cover.
2. Insert 4" duct into the inlet ring.
3. Fasten duct into place using at least 3 sheet met-
al screws evenly spaced around the inlet ring.
Refer to Figure 2.
4. Remove the barometric draft control unless it is
in the same atmospheric
pressure zone as the
inlet.
On the outside of the home use a 90 ° elbow pointed
downward with a 1/4" mesh screen over its opening.
The air inlet elbow must be located above the snow
line and in such a way as to prevent leaves and/or
other debris from blocking the air flow. Such debris
will prevent proper operation of the burner. Refer to
local codes for proper location of inlet.