2,
Screw in leveling legs
diamond
marking
Examine leveling legs and find diamond marking. Screw legs
into leg holes by hand. Use a wrench to finish turning legs
until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room to connect the
exhaust vent.
For mobile
home use
Gas dryers must be securely fastened to the floor.
Mobile home installations
require a Mobile Home Installation
Hold-down
Kit. For ordering information
please reference the
"Dryer User Instructions."
GAS DRYER POWER
HOOKUP
Gas Supply
Requirements
Explosion
Hazard
Use a new CSA international
approved gas supply line.
Install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
8
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information
is located on the rating
plate in the door well of your dryer. If this information
does
not agree with the type of gas available, please reference
the "Assistance
or Service" section of the "Dryer User
Instructions."
LP gas conversion:
Conversion must be made by a qualified
technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting the serving gas supplier.
iMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
Gas supply line
[]
1/2" NPT pipe is recommended.
[]
3/8" approved tubing is acceptable for lengths under
20 ft. (6.1 m) if local codes and gas supplier permit.
[]
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection,
immediately upstream of the gas
connection to the dryer (see illustration).
[]
Must include a shut-off valve:
in the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shut-off valve must be installed in
accordance
with the B149.1, Natural Gas and Propane
Installation Code. It is recommended
that an individual
manual shut-off valve be installed within six (6) feet (1.8 m)
of the dryer.
The shut-off valve location should be easy to reach for opening
and closing.
E
B
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection
requirements
There are many methods by which your gas dryer can be
connected to the gas supply. Listed here are some guidelines
for two different methods of connection.
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard for
connectors
for gas appliances, ANSI Z21.24 or CSA 6.10.

Hide quick links: