Admiral AED4675YQ0 Installation Instructions Manual

29" wide models

Advertisement

ELECTRIC
DRYER
"WIDE
INSTALLATI N INSTR
MODELS - U.S.A. ONLY
CTIONS
Para obtener acceso al manual de uso y cuidado en espa_ol, o para obtener informaci6n adicional acerca de su producto, visite:
www.whirlpool.com
Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo y de serie dentro de la cavidad superior de la puerta.
Table of Contents
DRYER SAFETY .........................................................................
2
.............................................
2
Tools and Parts ......................................................................
2
.........................................................
3
........................................................
4
Instafl Leveling Legs ..............................................................
5
Electrical Connection ............................................................
6
VENTING ...................................................................................
12
.........................................................
12
Plan Vent System .................................................................
13
Venting Kits ..........................................................................
13
Instafl Vent System ..............................................................
14
Vent ........................................................................
15
Level Dryer ...........................................................................
15
.........................................
15
Reverse Door Swing (Optional) ..........................................
16
...................................................................
19
W10096987A
W10097001A=SP

Advertisement

Table of Contents
loading

Summary of Contents for Admiral AED4675YQ0

  • Page 1: Table Of Contents

    ELECTRIC DRYER INSTALLATI N INSTR CTIONS "WIDE MODELS - U.S.A. ONLY Para obtener acceso al manual de uso y cuidado en espa_ol, o para obtener informaci6n adicional acerca de su producto, visite: www.whirlpool.com Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo y de serie dentro de la cavidad superior de la puerta. Table of Contents DRYER SAFETY .................
  • Page 2: Dryer Safety

    DRYER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3: Location Requirements

    If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft.
  • Page 4 Dryer Dimensions Mobile home = Additional installation requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction 433/8 and Safety, Title 24, HUD Part 280).
  • Page 5: Instafl Leveling Legs

    If using a power supply cord: mnstaH Leve ing Legs Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be Excessive Weight Hazard at least 4 ft.
  • Page 6: Electrical Connection

    Eiectrica Connection Power Supp{y Cord Direct Wire Fire Hazard Fire Hazard Use 10 gauge solid copper wire. Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections. Disconnect power before making electrical connections.
  • Page 7 Power SuppMy Cord Connection Power supply cord strain relief 4owire Power Supply Cord Connection Attach power supply cord IMPORTANT: A 4-wire connection is required for mobile strain relief homes and where local codes do not permit the use of 3-wire connections.
  • Page 8 3owire Power Supply Cord Connection 5, Connect ground wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. 3/4" (19 mm) UL listed strain relief F.
  • Page 9 Direct Wire Connection Direct wire strain relief 4owire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile 1. Attach direct wire strain relief homes and where local codes do not permit 3-wire connections. Prepare your 4-wire cable for direct connection (127...
  • Page 10 3owire Direct Wire Connection and neutral wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Prepare your 3-wire cable for direct connection Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B).
  • Page 11 2, Connect neutral ground wire Connect neutral wire and neutral wire Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw. Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, silver-colored terminal block screw (B).
  • Page 12: Venting

    VENTING Exhaust hoods: Venting Requirements Must be at least 12" (305 ram) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow). 4" (102 mm)__'_ Fire Hazard Use a heavy metal vent. r_4,,÷l (102 rnrn) Do not use a plastic vent.
  • Page 13: Plan Vent System

    Alternate installations for close clearances Plan Vent System Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Recommended exhaust installations Refer to the manufacturer's instructions. Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
  • Page 14: Instafl Vent System

    Special provisions for mobile home installations: Vent System Chart The exhaust vent must be securely fastened to a noncombustible (Long Vent Models Only) portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Number Type Box/Iouvered,...
  • Page 15: Connect Vent

    NOTE: The dryer must be level for the moisture sensing system Connect Vent to operate correctly. Not Level LEVEL Not Level 2, Tighten and adjust leveling legs Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean.
  • Page 16: Reverse Door Swing (Optional)

    [_ When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door. if you do not feel heat, turn off dryer, and check the following: There may be 2 household fuses or circuit breakers for the dryer.
  • Page 17 insert screws in hinge holes on dryer cabinet NOTE: Two people maybe needed to reinstall door. Open dryer door. Remove bottom screws from dryer cabinet side of hinges. Loosen (do not remove) top screws from Insert screws into bottom holes on left side of dryer cabinet. dryer cabinet side of hinges.
  • Page 18 Remove screws from door Attach door hinges Remove screws at top, bottom, and side of door (4 screws). Keep door screws separate from hinge screws as they are diferent sizes. Holding door over towel on dryer, grasp sides of outer door and lift to separate it from inner door.
  • Page 19: Troubleshooting

    1 O, Remove and transfer 1 2, Remove door strike plug hinge hole plugs Remove door strike plug. Insert the door strike removed in Use a small, flat-blade screwdriver to gently remove 4 hinge Step 9 into hole and secure with screw. Insert door strike hole plugs on left side of dryer cabinet.
  • Page 20 W10096987A W10097001A=SP 2/10 © 2010 Whirlpool Corporation. @ Registered Trademark/TM Trademark of Whirlpool, U.S.A. Printed in U.S.A. All rights reserved...

Table of Contents