Gas Dryer Power Hookup; Gas Supply Requirements - Admiral AGD4675YQ2 Installation Instructions Manual

29" and 27" wide models gas and electric
Table of Contents

Advertisement

Available languages

Available languages

2.
Screw in leveling legs
diamond
marking
Examine leveling legs and find diamond marking. Screw legs
into leg holes by hand. Use a wrench to finish turning legs
until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room to connect the
exhaust vent.
For mobile
home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation
Hold-down
Kit. For ordering information,
please reference the
"Use and Care Guide."
GAS DRYER POWER HOOKUP
Gas Supply
Requirements
Explosion Hazard
Use a new CSA international
approved gas supply line.
Install a shut-off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion, or fire.
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certified by CSA international for LP (propane or butane) gases
with appropriate conversion.
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information
is located on the rating
plate in the door well of your dryer. If this information
does
not agree with the type of gas available, please reference the
"Assistance
or Service" section of the "Use and Care Guide."
LP gas conversion:
Conversion
must be made by a qualified
technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting the serving gas supplier.
iMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.