Venting Kits - Admiral AGD4675YQ2 Installation Instructions Manual

29" and 27" wide models gas and electric
Table of Contents

Advertisement

Available languages

Available languages

Alternate
installations
for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance
installations are shown.
Refer to the manufacturer's
instructions.
Special
provisions
for mobile
home
installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Over-The-Top installation
(also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1=800=901=2042, or visit us
at www.applianceaccessories.com,
in Canada, call
1=800=807=6777 or visit us at www.whirlpooiparts.ca.
Part Number
Descriptions
8171587RP
0-5" Metal vent periscope
4396037RP
0"-18" Metal vent periscope
4396011RP
18"-29"
Metal vent periscope
4396014
29"-50"
Metal vent periscope
4392892
In-Wall metal DuraVent
TM
Periscope
W10186596
4-way vent kit - universal grey (27" Dryers Only)
4396028
Sure Connect
TM
venting kit
(over-the-top
installation)
4396009RP
5' Universal connect vent, flexible dryer venting
4396010RP
6' SecureConnect
TM
vent, flexible dryer venting
4396013RB
Dryer vent installer's kit
4396033RP
5' flexible dryer venting with clamps
4396727RP
8' flexible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe
TM
close elbow
4396007RW
Through-the-wall
vent cap
4396008RP
4" steel dryer venting clamps - 2 pack
8212662
Flush mounting Iouvered vent hood 4"
Determine
vent path:
[]
Select route that will provide straightest
and most direct path
outdoors.
[]
Plan installation to use fewest number of elbows and turns.
[]
When using elbows or making turns, allow as much room
as possible.
[]
Bend vent gradually to avoid kinking.
[]
Use as few 90 ° turns as possible.
Determine
vent length and elbows
needed
for best
drying
performance:
[]
Use following "Vent System Chart" to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Chart." Exhaust systems longer than those
specified will:
[]
Shorten life of dryer.
[]
Reduce performance,
resulting in longer drying times and
increased energy usage.
The "Vent System Chart" provides venting requirements that
will help achieve best drying performance.
Vent System
Chart
Number
of
90 ° turns or
elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
Angled
hoods
hoods
64 ft. (20 m)
58 ft. (17.7 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4m)
38 ft. (11.6m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90 ° turn inside the dryer. To determine
maximum exhaust length, add one 90 ° turn to the chart.
11