9 FRONT PANEL INTERFACE
9.11.1 Meter view 1 – Home View
HOME
- - - -
FAULT/WARNING
CL3W
Y-10
-24
FAULT/WARNING
1 AUX
Y-10SUB
-50
FAULT/WARNING
Figure 9-14
Home View is the default view. Any names (labels)
which have been assigned to the Module inputs and
outputs are displayed; input and output signal levels
can be monitored, and any faults and/or warnings
indicated by red or yellow soft button LEDs are given
textual explanation.
* See tables 9-2 and 9-3 for details of actual text
displayed for each fault/warning type.
Frame block:
▸
Line 1
HOME flag – confirms Home view
▸
Line 2
Frame name – displays Frame ident
confirming "which PLM this is". A row of hyphens
is displayed if no name has been assigned.
▸
Line 3
(blank)
▸
Line 4
Frame fault/warning – In the event of
a Frame fault or warning, text describing the
problem is displayed here*
Input blocks:
▸
Line 1
Module name – displays name given to
Dolby Lake processing Modules A and B (if any).
This data item is also displayed in most of the
parameter adjustment pages in Menu Mode.
▸
Line 2
Fingerprint name
▸
Line 3
Input meter showing signal level at the
input to the Dolby Lake processing Module. A
numeric indication in dB of the difference between
the signal level and input clip level is also provided
at the right-hand end of the meter.
▸
Module fault/warning – In the event of
Line 4
a Module fault or warning, text describing the
problem is displayed here.
block 4 is unused in METER mode.
36 PLM Series Operation Manual
HI
A
-09
1
-02
FAULT/WARNING
MID
A
-13
∞
2
-
FAULT/WARNING
LO
A
-11
∞
3
-
FAULT/WARNING
SUB
B
-45
∞
1
-
FAULT/WARNING
Output blocks:
▸
Channel name – displays name assigned
Line 1
to PLM's power output channel (e.g. LF1 etc.).
This data item is also displayed in most of the
parameter adjustment pages in Menu Mode.
▸
Line 2
Output meter showing signal level at
the PLM's power output stage, with full-scale
indication representing output clip. A numeric
indication of signal level in dBu is also provided
at the right-hand end of the meter.
▸
Line 3
Gain reduction meter showing degree
of limiting being applied by the ISVPL and/or the
LimiterMax within the Dolby Lake processing
system.
▸
Line 4
Fault/warning indication for the PLM's
power output stage. In the event of a power
output channel fault or warning, text describing
the problem is displayed here.*
9.11.2 Meter View 2 – Module View
MODULE METERS
FAULT/WARNING
CL3W
-24
1 AUX
-50
Figure 9-15
Module View provides further signal level information
in the form of additional power output meters.
Frame block:
▸
MODULE METERS flag – confirms
Line 1
Module view
▸
Line 2
(blank)
▸
(blank)
Line 3
▸
Frame fault/warning – in the event of
Line 4
a Frame fault or warning, text describing the
problem is displayed here.*
Input blocks:
▸
Line 1
Module name – displays name given
to Dolby Lake processing Modules A and B (if
any)
∞
V
-
A
I
1
P
L
∞
V
-
A
I
2
P
L
V
∞
-
A
I
3
P
L
V
∞
-
B
I
1
P
L