Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout.
A
S
...............
........................
,
°
--
._"@
(
A. Knockout
B. Terminal box cover
4. Install a UL listed or CSA approved strain relief.
I
F
A. Home power supply cable
B. Terminal box cover
C. UL fisted or CSA approved strain relief
D. Green (or bare) wire connected
to yellow-green
wire
E. White wires
F. Black wires
5. Run 3 wires, black, white and green (14 AWG), in 1/2"conduit
from service panel to terminal box. Use caulking to seal
opening.
6. Use UL listed wire connectors
and connect black wires (F)
together.
7. Use UL listed wire connectors
and connect white wires (E)
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
8. Use UL listed wire connectors
and connect green (or bare)
wire with yellow-green
wire (D).
9. Tighten strain relief screws.
10. Replace terminal box cover.
11. Check all light bulbs to make sure they are secure in their
sockets.
12. Reconnect power.
1=
Insert 4 screws on the bottom of the chimney structure (in
corresponding
position to the keyhole slots on the hood
canopy).
:\
c_
A. Four screws
2. Lift hood canopy so that the large end of the keyhole slots are
over the 4 screws on the bottom of the chimney structure.
3. Push the hood canopy so that the 4 screws are in the narrow
end of the keyhole slots. Securely tighten the screws.
4. Install the remaining 4 screws and securely tighten.
\ /
Front