Make Electrical Connection - IKEA W10502581D Use & Care Manual

30"(76.2cm) island-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily
remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4. Seal all connections
with vent clamps. Continue with "Range
Hood Installation"
in this section.
Range Hood Installation
1.
2=
Using 2 or more people, lift the range hood assembly and
attach it by snapping the vertical supports to the spring clips
in the upper horizontal support bracket that is mounted to the
ceiling.
Install 16 - 4.2 x 8 mm T20 ®screws, and tighten to secure.
A
....
!
!
A. Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections
with
vent clamps.
3. Use caulk to seal all openings.
Electrical Shock Hazard
Disconnect
power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover using a TIO Torx ®drive (or the
T10 adapter provided) to remove screws.
3=
4=
Remove the knockout in the terminal box and install a UL
listed or CSA approved 1/2"strain relief.
A. Knockout
B. Terminal box
C. Terminal box cover
Run home power supply cable through strain relief, into
terminal box.
E
F
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
E Green (or bare) and yellow-green
ground wires
5. Use UL listed wire connectors
and connect black wires (C)
together.
6. Use UL listed wire connectors
and connect white wires (E)
together.