OPERATION AND SERVICE INFORMATION
Read all of manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notes, Cautions and Warnings
Before charging the batteries, inspect the plug of the bat-
tery charger and vehicle receptacle housing for dirt or
debris.
Charge the batteries after each days use.

Monthly

Inspect all wiring for fraying, loose terminations,
corrosion or deterioration of insulation.
Check that the electrolyte level is correct and add
suitable water as required.
Clean the batteries and wire terminations.

Electrolyte Level and Water

The correct level of the electrolyte is 1/2" (13 mm) above
the plates in each cell (Ref Fig. 24 on page 20).
Expansion
Space
1/4" to 3/8"
(6 to 10 mm)
Plates
Ref Cel 1

Fig. 24 Correct Electrolyte Level

This level will leave approximately 1/4" - 3/8" (6 - 10 mm)
of space between the electrolyte and the vent tube. The
electrolyte level is important since any portion of the
plates exposed to air will be ruined beyond repair. Of
equal importance is too much water which will result in
electrolyte being forced out of the battery due to gassing
and the increase in volume of the electrolyte that results
from the charging cycle.
Do not overfill batteries. The charging
cycle will expel electrolyte and result in
component damage.
A battery being charged will 'gas' with the majority of the
gassing taking place at the end of the charging cycle.
This gas is hydrogen which is lighter than air. Water and
sulfuric acid droplets will be carried out of the battery
vents by the hydrogen gas; however, this loss is minimal.
If the battery electrolyte level is too high, the electrolyte
will block the vent tube and the gas will force it out of the
Page 20
Vent Cap
Gas Vent
Vent
1/2" (13 mm
Electrolyte level should be
at least 1/2" (13 mm) abov
the plates and 1/4" to 3/8"
(6 to 10 mm) below bottom
of vent
Owner's Manual and Service Guide
vent tube and battery cap. The water will evaporate but
the sulfuric acid will remain where it can damage vehicle
components and the storage facility floor. Sulfuric acid
loss will weaken the concentration of acid within the elec-
trolyte and reduce the life of the battery.
Over the life of the battery, a considerable amount of
water is consumed. It is important that the water used be
pure and free of contaminants that could reduce the life
of the battery by reducing the chemical reaction. The
water must be distilled or purified by an efficient filtration
system. Water that is not distilled should be analyzed
and if required, filtration installed to permit the water to
meet the requirements of the water purity table (Ref Fig.
25 on page 20).
Impurity
Color ................................................................................Clear
Suspended ..................................................................... Trace
Total Solids....................................................................... 100
Calcium & Magnesium Oxides .......................................... 40
Iron ..................................................................................... 5
Ammonia ............................................................................ 8
Organic & Volatile Matter................................................... 50
Nitrites ................................................................................ 5
Nitrates .............................................................................. 10
Chloride .............................................................................. 5

Fig. 25 Water Purity Table

Even if the water is colorless, odorless, tasteless and fit
for drinking, the water should be analyzed to see that it
does not exceed the impurity levels specified in the table.
Automatic watering devices such as the one included in
the Battery Maintenance Kit (P/N 25587-G01) can be
used with an approved water source (Ref Fig. 26 on
page 21). These watering devices are fast and accurate
to use and maintain the correct electrolyte level within the
battery cells.
The watering device should only be used if the
electrolyte level is less than 1/2" (13 mm)
above top of plates.