Make Electrical Power Supply Connection To Range Hood - KitchenAid KXW4436YSS Installation Instructions And Use And Care Manual

30",36"and48"(76.2 cm,91.4cmand121.9cm) commercial style wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

6. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the
"Make Electrical Power Supply Connections to Range Hood"
section).
B
A
A. UL listed or CSA approved
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
7. Go to "Make Electrical Power Supply Connection to Range
Hood" section.
Make Electrical Power Supply Connection to
Range Hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate terminal box inside of the range hood.
A. Terminal box cover
B. Knockout in canopy back into terminal box
C
D
E
F
G
H
I
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow) wire
I. 6-wire connector assembly
A
B
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
NOTE: When using an in-line blower motor system, the green (or
green/yellow) ground wire in the conduit from the In-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
E
F
" (1.3 cm) strain relief
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents