Make Electrical Power Supply Connection To Range Hood; Prepare Location; Install Range Hood - KitchenAid KXI9736YSS0 Installation Instructions And Use & Care Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-style island mount canopy hood
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical shock.
8. Connect the green (or yellow/green)
ground wire to the
green/yellow
ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical
Connection
Inside Range Hood Between
In-line
Blower System and Range Hood
1. With the range hood mounted (see the "Install Range Hood"
section), locate the wiring cable connector
inside the range
hood.
2. Connect the 6-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the range hood.
r"
3. Locate the terminal box inside the range hood and install a
1/2"(1.3 cm) UL listed or CSA approved strain relief (see
"Complete
Preparation"
in the "Prepare Location" section).
4. Run the wire ends from the 6-wire connector assembly
through the 1/2"(1.3 cm) strain relief, leaving enough wire
length to make the wiring connections.
Tighten the strain
relief screws.
5=
6=
Connect the wires from the 6-wire connector assembly to the
wires from the wiring conduit inside the range hood terminal
box.
Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow)
ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors
(see the
"Make Electrical Power Supply Connection
to Range Hood"
section).
B
C
A
7=
A. UL fisted or CSA approved
½" (1.3 cm) wiring conduit
B. UL fisted wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. 6-wire connector assembly
Go to "Make Electrical Power Supply Connection
to Range
Hood" section.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kxi9748yss0

Table of Contents