Venting Requirements - KitchenAid KXW4436YSS Installation Instructions And Use And Care Manual

30",36"and48"(76.2 cm,91.4cmand121.9cm) commercial style wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Installation Dimensions
30" (76.2 cm), 36" (91.4 cm),
(If installed between cabinets)
Bottom of canopy
to cooking surface
18" (45.7 cm) min.
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
A. For installations with canopy
only:
78" (198.1 cm) minimum above
electric cooking surface
84" (213.4 cm) minimum above
gas cooking surface
IMPORTANT:
Minimum distance "X": 24" (61 cm) from electric cooking
surfaces
Minimum distance "X": 30" (76.2 cm) from gas cooking
surfaces
Suggested maximum distance "X": 36" (91.4 cm)

Venting Requirements

Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
or 48" (121.9 cm)
cabinet opening width
Min. cabinet
opening width
X
13" (33.0 cm)
B. For installations with optional
duct cover:
90" (228.6 cm) minimum
above electric cooking
surface
96" (243.8 cm) minimum
above gas cooking surface
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
A B
Makeup air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
Roof Venting
B
A. Roof cap
B. 10" (25.4 cm)
round vent
Wall Venting
Wall Venting
A
B
B
A
A. Wall cap
A. Wall cap
B. 10" (25.4 cm)
B. 10" (25.4 cm)
round vent
A
round vent