To Edit or Clear a Saved Job
Follow these steps to make changes to an existing job.
1. Press MENU. Use the up/down arrows to highlight MEMORY. Press SELECT.
2. Use the up/down arrows to select the correct job program to edit (Memory 1, Memory 2, etc.).
3. If you need to review the stored values for pressure and vacuum, press and hold SETTINGS.
You can adjust the pressure and vacuum from this screen, or you can make adjustments from
TIMED mode. However, note: you can only adjust the dispense time setting from the TIMED
mode screen.
4. Press MENU again.
5. Press TIMED to return to TIMED mode in the selected program.
6. Adjust the settings for dispense time, air pressure and vacuum as needed to achieve the correct
deposit size.
7. Press MENU.
8. Use the up/down arrows to highlight SAVE JOB. Press SELECT.
9. Use the up/down arrows to again select the correct job program.
10. Press SAVE. This automatically saves the changed settings and returns you to the Home screen.
Note: to clear all settings in a specific job program, simply set the time, pressure and vacuum to 0 in
step 6 and follow the other steps as noted.