Hach 900 MAX Instrument Manual page 13

Refrigerated sampler
Table of Contents

Advertisement

Intake Purge
Pump/Controller
Housing
Internal Clock
Manual Sample
Intake Rinse
Intake Retries
Intake Tubing
Intake Strainers
Factory Installed Options
pH/Temperature/ORP Meter
Control/Logging
pH/Temperature Sensor
Measurement Range
Operating Temperature
Dimensions
Dissolved Oxygen Meter
Control/Logging
Measurement Method
Sensor
Measurement Range
Resolution
Accuracy
Operating Temperature
Dimensions
Conductivity Meter
Control/Logging
Sensor
Measurement Range
Resolution
Accuracy
Operating Temperature
Dimensions
8990spc.fm
Air purged automatically before and after each sample; duration automatically compensates
for varying intake line lengths.
High impact injection molded ABS; submersible, watertight, dust tight, corrosion & ice
resistant; NEMA 4X,6.
Indicates real time and date; 0.007% time base accuracy.
Initiates a sample collection independent of program in progress.
Intake line automatically rinsed with source liquid prior to each sample, from 0 to 3 rinses.
Sample collection cycle automatically repeated from 0 to 3 times if sample is not obtained on
initial attempt.
3
3
¼ in. and
/
in. ID vinyl or
8
®
Choice of Teflon
and 316 stainless construction, and all 316 stainless steel in standard size
and low profile for shallow depth applications.
Field selectable to log pH/temperature or ORP independent of sample operation or to control
sample collection in response to volume exceeding low/high setpoints.
Temperature compensated; impact resistant ABS plastic body
Combination electrode with porous Teflon junction
0 to 14 pH, -10 to 105 °C
-18 to 80 °C (0 to 176 °F)
1.9 cm dia. × 15.2 cm long (0.75 in. × 6 in.) with 1.9 cm (0.75 in.) mpt cable end
Field selectable to log dissolved oxygen independent of sampler operation or to control
sample collection in response to volume exceeding low/high setpoints.
Galvanic
Temperature compensated; impact resistant polypropylene body
0 to 20 mg/L
0.01 mg/L
±3% of reading or 0.1 mg/L
0 to 50 °C (32 to 122 °F)
1.7 mm diameter × 15.7 cm long (0.65 in. × 6.25 in.) with 1.9 cm (0.75 in.)
Field selectable to log conductivity independent of sampler connection or to control sample
collection in response to volume exceeding low/high setpoints.
Temperature compensated; impact resistant polypropylene body
0 to 20 mS/cm
0.01 mS/cm or 1 mS/cm
±2% of reading or 0.01 mS
0 to 50 °C (32 to 122 °F)
1.7 cm diameter × 15.2 cm long (0.67 in. x 6 in.) with 1.9 cm (0.75 in.) mpt cable end
/
in. ID Teflon* lined polyethylene with protective outer cover.
8
Specifications
Page 11