Summary of Contents for Hach sension ph31

  • Page 1 DOC022.97.90249 ™ sensION + pH31 03/2013, Edition 3 User Manual Manuel d'utilisation Manual del usuario Manual do Usuário 用户手册 取扱説明書 사용 설명서 คู  ม ื อ ผู  ใ ช...
  • Page 2: Specifications

    Specifications Specification Details Specifications are subject to change without notice. Display Liquid crystal, backlit, 128 x 64 dots Keyboard PET with protective treatment Specification Details Certification Dimensions 35 x 20 x 11 cm (13.78 x 7.87 x 4.33 in.) Weight 1100 g (2.43 lb) General information Meter enclosure...
  • Page 3: Installation

    C A U T I O N Figure 1 Meter components Indicates a potentially hazardous situation that may result in minor or moderate injury. N O T I C E Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special emphasis.
  • Page 4 English 5...
  • Page 5: Connect To Ac Power

    Connect to AC power Figure 2 Connector panel D A N G E R Electrocution hazard. If this equipment is used outdoors or in potentially wet locations, a Ground Fault Circuit Interrupt (GFCI/GFI) device must be used to connect the equipment to its main power source.
  • Page 6: User Interface And Navigation

    User interface and navigation Figure 3 AC power connection User interface Keypad description 1 RETURN key: cancel or exit the 5 DOWN key: scroll to other options, current menu screen to the change a value previous menu screen 2 MEASUREMENT key: confirm the 6 ON/OFF: turn on or turn off the selected option meter...
  • Page 7: Turn The Meter On And Off

    Change the language Figure 4 Single screen display The display language is selected when the meter is powered on for the first time. 1. Use the to select a language from a list. 2. Confirm with . The measurement screen shows DATA OUTPUT. 3.
  • Page 8: Calibration Procedure

    Option Description Option Description Cal. frequency Calibration reminder—can be set between 0–7 days Data introduction Manual probe constant introduction. (default daily). The display shows the remaining time to Theoretical calibration The probe calibration data is replaced at 25 °C the new calibration. Refer to Set the calibration reminder (77 °F).
  • Page 9: Advanced Operation

    2. Use the to change the following settings. Confirm every entry. View the calibration data Data from the most recent calibration can be shown. Option Description 1. From the main menu use the to select DATA LOGGER. Resolution Select the resolution: 1, 0.1, 0.01 (default) or 0.001 Confirm.
  • Page 10: Select The Data Output

    3. Use the to select Adjust the display contrast Option Description 1. From the main menu use the to select SYSTEM. Confirm. Automatic A consecutive number will be automatically assigned to every 2. Use the to select Display contrast and confirm. sample.
  • Page 11: Data Logger

    Change the stirring settings 4. Use the to select The magnetic stirrer can be turned on and the stirring speed can be Option Description changed in the Stirring menu. Measurement data Measurement data—stores automatically each time a sample is measured 1.
  • Page 12: Report Output

    Maintenance Report output W A R N I N G N O T I C E Multiple hazards. Do not disassemble the instrument for maintenance or service. The data output (printer or PC) needs to be selected first, so that the Type of If the internal components must be cleaned or repaired, contact the report menu is available (refer to Select the data output...
  • Page 13: Replace The Magnetic Stirrer

    Replace the magnetic stirrer If the magnetic stirrer does not start, follow the numbered steps to replace the magnetic stirrer. 14 English...
  • Page 14 English 15...
  • Page 15: Troubleshooting

    Troubleshooting Table 2 Calibration warnings and errors (continued) Error/Warning Solution Refer to the following table for common problem messages or symptoms, possible causes and corrective actions. Electrode in poor Examine the probe: Clean the probe (refer to Clean the conditions. probe on page 13 for more information);...
  • Page 16: Replacement Parts And Accessories

    Replacement parts and accessories Replacement parts and accessories (continued) Note: Product and Article numbers may vary for some selling regions. Contact the Description Item no. appropriate distributor or refer to the company website for contact information. pH buffer solution 10.01, 1000 mL LZW9472.99 Replacement parts Electrolytic solution (KCl 3M), 125 mL...
  • Page 17: Standard Solutions

    Replacement parts and accessories (continued) Table 4 pH, ORP (mV) and temperature values (continued) Temperature Description Item no. °C °F Magnetic stirrer with sensor holder, for sensION+ MM LZW9319.99 benchtop 2.01 4.22 7.04 8.83 — — 3x50 mL printed beakers for benchtop pH calibration LZW9110.97 2.01 4.30...