CONFIGURING MOTHER BOARD JUMPERS

With the pre-installed SETUP utility, you can set desired passwords to protect the data stored in the
server against access from unauthorized users. When you forget the passwords, however, you may
want clear them. The following describes how to clear these passwords. You can also use the
following procedure to clear the CMOS data in the server.
IMPORTANT:
Clearing the CMOS data resumes the factory-set configuration data.
After clearing CMOS, you must run the BIOS SETUP utility and
execute the following menus to reconfigure your mother board.
– Load Setup Defaults in the Exit menu
– Memory Retest of Memory Configuration in the Advanced menu
– Processor Retest of Processor Settings in the Main menu
Refer to "RAID System Configuration" described earlier in this
chapter for RAID configuration jumper setting.
Do not change any other switch settings. Any change may cause the
server to fail or malfunction.
To clear passwords or the CMOS data, use the jumper switch on the mother board of the server. The
following figure illustrates the jumper switch location.
Pin for protecting/
clearing the password
Front
Protect
Clear
Configuring Your Server 4-79
Protect
Clear
Pin for protecting/
clearing the CMOS
contents
Rear