Gas Regulator - Blue Seal GP513 Installation And Operation Manual

Evolution series
Hide thumbs Also See for GP513:
Table of Contents

Advertisement

Gas Regulator

NOTE: Gas
regulator
convertible between Natural Gas
and LP Gas, but it's outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn 'On' gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure burner operating pressure at gas valve outlet
test point with burner operating at 'High Flame' setting.
4.
Verify operating pressure remains correct (Re-adjust regulator if required).
5.
Screw cap nut back onto regulator.
Gas Type Labels
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Commissioning
Before leaving installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a 'Commissioning' check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE: If it is not possible to get the appliance to operate correctly, shut off the gas supply and
contact the supplier of this appliance.
Gas Conversion and Specifications
supplied
is
Warning
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
21
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Cap Nut