Troubleshooting
Solar Controller Errors
Error representation on
display
Flashing
Flashing
Error representation
no display function
Solar Controller does not work
Symbol "pump" rotates, but pump
does not work
Temperature display varies strong
in short time intervals
Possible Cause
•
Sensor wire broken
•
Defective sensor
•
Short circuit in sensor wire
•
Defective sensor
Possible Cause
•
Lost main power
•
Controller internal safety fuse failed
•
Appliance defect
•
Solar Controller is in manual opera-
tion
•
no demand for unit to be on
•
Loose wiring
•
Interference from neighboring wires
•
Long sensor wires lengthened without
shielding
•
Controller or Sensor defect
Corrective Measures
•
Check wire
•
Check sensor resistance, if necessary
replace sensor
•
Check wire
•
Check sensor resistance, if necessary
replace sensor
Corrective Measures
•
Check to ensure that circuit breaker
has not tripped
•
Check other 120V components on
circuit to see if they are working
•
Check safety fuse in controller, replace
it by a new one, type 2A/T, if necessary
•
Consult installer
•
Exit menu "Manual operation"
•
Wait until temperatures place demand
on system to turn on
•
Check pump(s) wiring connections
•
Consult Installers
•
Adjust location of wires
•
Shield Sensor Wires
•
Consult Installers
39