Dimplex 200 AIR D/2 Installation Manual
Dimplex 200 AIR D/2 Installation Manual

Dimplex 200 AIR D/2 Installation Manual

Heat pump water heater
Table of Contents

Advertisement

Quick Links

Heat pump
water heater
using exterior or non-heated ambient air
Installation manual
Manual ref. : 1898150
Edition n° 22.17
The information contained in this document is non-contractual. Auer reserves the right to modify the technical specifi cations or characteristics of any of their appliances without prior notice.
Necessary technical data
-in appendix-
HEAT PUMP
WATER HEATER
200 AIR D/2
Ref. 935111
HEAT PUMP
WATER HEATER
270 AIR D/2
Ref. 935112
Made in
FRANCE

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex 200 AIR D/2

  • Page 1 Heat pump water heater using exterior or non-heated ambient air HEAT PUMP Installation manual WATER HEATER 200 AIR D/2 Ref. 935111 HEAT PUMP WATER HEATER 270 AIR D/2 Ref. 935112 Made in FRANCE Necessary technical data Manual ref. : 1898150 -in appendix- Edition n°...
  • Page 2: Table Of Contents

    CONTENTS 5.9 - Installer menu ..................15 1 - SAFETY ............3 5.9.1 - PV mode ........................15 2- RECOMMENDATIONS ........5 5.9.2 - Adjusting the operating settings ..............16 2.1 - Storage ....................5 ANTI-BACT 5.9.2.1 - -anti-legionellosis cycle........16 fan mode ..............16 2.2 - Transport ....................5 5.9.2.2 - T°C.
  • Page 3: Safety

    Preserving these documents Danger resulting from improper use • This manual and all other relevant documents should be given to Any work carried out by an unqualifi ed person the system user. can result in damage to the installation or in The system user should keep these manuals for future reference.
  • Page 4 • Drainage : Turn off the power supply and the Protect the appliance with: cold water, open the hot water valves and then • an 8 A all-pole circuit breaker with a set the safety group to the drainage position. contact opening of at least 3mm.
  • Page 5: 2- Recommendations

    2- RECOMMENDATIONS If tipped, the centre of gravity will shift towards the top: handle with care. The appliance can only function when filled with water. Never turn on the appliance if the tank has not been properly filled with water and completely purged of air. 2.1 - Storage Risk of tipping STORAGE PRECAUTIONS:...
  • Page 6: Presentation

    3 - PRESENTATION 3.2 - Technical specifi cations and performances 3.1 - Dimensions CET* CET* 200 AIR 270 AIR 3.1.1 - 200 L Heat pump water heater Heat pump performance Nominal volume Max.input power 1900 1900 Air temperature range -7 to +35 -7 to +35 °C DHW* temperature with heat...
  • Page 7: Eu Declaration

    3.3 - EU declaration This device complies with international electrical safety standards IEC 60335-1, IEC 60335-2-21, IEC 60335-2-40. The CE marking present on the device attests to its conformity with the following Community Directives, of which it meets the essential requirements: •...
  • Page 8: Air Connection

    4.2.3- Piping accessories 4.2- Air connection Piping accessories are available to order and are designed for a simple 4.2.1 - Without piping and effi cient heat pump water heater connection. If installed without piping, the appliance must be installed in non- The pipes (Ref.
  • Page 9 • The following materials should be used for the domestic hot water circuit: - copper - stainless steel - brass - plastic If the materials used in the domestic hot water circuit are incompatible, corrosion damage may occur. Consequently, the appliance should always be connected to copper domestic hot water pipes with a cast-iron or steel link, or with dielectric connections (not supplied) to avoid an iron/copper galvanic bridge.
  • Page 10: Condensates Drainage

    4.5.1.1 - Peak/off -peak hours contact 4.4 - Condensates drainage It is possible to connect the dry contact from the electricity - The condensates tube should not be directly connected to a drain. counter to the heat pump water heater without programming It must lead off into open air in a siphon which has been added from the control panel.
  • Page 11: Electricity Provider Contact

    4.5.1.3 - Electricity provider contact To prevent the electrical back-up from running during peak hours, connect the dry contact originating from the electricity counter, to terminal 1. - Switch open = Back-up not allowed to run - Switch closed = Back-up allowed to run By choosing load shedding level 0 or 1 (see §...
  • Page 12 HEAT PUMP WATER HEATER 200 -270L AIR D/2 - INSTALLER MANUAL...
  • Page 13: Set-Up And Use

    5 - SET-UP AND USE 5.2 - Setting the language Deterioration risk: the water tank must be fi lled before the appliance is switched The language must be selected when the appliance is turned on or connected to a power supply. on for the fi rst time.
  • Page 14: Setting The Desired Water Temperature

    5.4 - Setting the desired water 5.5 - Holiday/temporary standby mode temperature h ol i d a y « » mode puts the appliance on standby while the frost protection mode remains active. This function can be 5.4.1 - PV mode inactive programmed to run between 1 and 99 days, and is in eff ect as The water temperature is adjustable from 30°C to 65°C.
  • Page 15: Programming

    5.8 - Programming Programming enables you to define the periods of time the appliance runs in m on day «Economy», «Comfort» or «Frost protection» modes. The electrical back-up is not Select day allowed to run when the appliance is in «Economy» mode. •...
  • Page 16: Adjusting The Operating Settings

    7. Turn the dial to select the primary function: • If the set temperature for domestic hot water is already 60°C - Menu → INST. MENU → MODE PV → PRIORITY (see § «Setting the desired water temperature»), there will be no anti-legionellosis cycle as it is already running continuously.
  • Page 17: Level Authorised During Peak Hours

    Load shedding 5.9.3 -Locking the keyboard 5.9.2.4 - -Level authorised during peak hours Permanent and automatic locking When load shedding is activated you can choose to prevent certain The «locking» menu enables you to create three possible levels of elements from running (Electrical resistance and compressor). locking for accessing the menus.
  • Page 18: Resetting Parameters

    5.9.4 - Resetting parameters 5.9.5 - Read data Resetting the parameters allows you to go back to the default The «READ DATA» menu shows you, in real time, the information settings. given by the sensors. Go to the «Installer», menu and turn the dial to «Reset PAR.». In the «Installer»...
  • Page 19: Maintenance And Troubleshooting

    6 - MAINTENANCE AND .../... TROUBLESHOOTING → The refrigerant circuit containing fl ammable refrigerant complies with national gas regulations. In order to maintain effi ciency and improve durability it → In case of operating on the refrigerant circuit: is advised that an annual maintenance check be carried out by a qualifi ed professional.
  • Page 20: Modifi Cation

    6.4 - Modifi cation • Condensates are not draining (water present under the appliance) Any modifi cation of the device is prohibited. Any replacement of Check that: components must be done by a professional with original parts • The drainage system is not blocked: from the manufacturer.
  • Page 21: List Of Spare Parts

    6.10 - List of spare parts Rep. 200L 270L Description Regulation / display B1244096 B1244096 C3S electronic circuit board controller B4992570 B4992570 Programmed display (200L/270L) B4994474 Programmed display (270L-1 exch.) B1244576 B1244576 Temperature sensor lg460mm B1244577 Temperature sensor lg00mm B1244575 Temperature sensor lg1200mm B4993072 B4993072...
  • Page 22: Error Message Codes: Errors, Solutions And Operating In Case Of Error

    6.11 - Error message codes: errors, solutions and operating in case of error N.B. : Errors can be dismissed by briefl y pressing the dial (manual reset) Temporary operation measures Display Error Probable causes Solutions while waiting for the problem to be solved •Voltage too high on electrical network...
  • Page 23 Temporary operation measures Display Error Probable causes Solutions while waiting for problem to be solved •The air and defrosting sensors are inverted on the electronics board •The defrosting and water sensors are inverted on the electronics •Reposition the temperature •Incorrect temperature sensor board sensors correctly on the main reading...
  • Page 24: Warranty

    7 - WARRANTY 7.1.2.3 - Installation site Cases (not limited to) where the warranty is void: • Placing the appliance where it can be subject to frost or other The tank is guaranteed against breakage for a period of fi ve (5) years, adverse weather conditions.
  • Page 25: Appendices

    8 - APPENDICES 8.1 - Performance statistics 8.1.1 - COP development 8.1.2 - Heating time The per formances are measured during a standardised This graph represents the heating time for a full tank depending on h e a t i n g c y c l e ( E N 1 6 1 4 7 ) w i t h c o l d w a t e r a t 1 0 ° C . the air and domestic hot water temperatures using the heat pump This graph represents the development of the COP depending on and without a back-up.
  • Page 26: Electrical Wiring Diagram

    8.2 - Electrical wiring diagram HP - High pressure - pressure switch CP - 25µF Compressor start-up capacitor C2 - 2µF fan capacitor C5.5 - 5.5µF fan capacitor SV - Defrosting valve RE - 1200W electrical resistance UTL - Electrical back-up temperature limiting safety thermostat AqL - Electrical back-up safety aquastat HPS - High pressure - pressure switch...
  • Page 27 NOTES HEAT PUMP WATER HEATER 200 -270L AIR D/2 - INSTALLER MANUAL...
  • Page 28 Any work carried out on the refrigerant circuit must be carried out by a qualifi ed professional with a Category 1 certifi cate of aptitude. Releasing refrigerant gasses into the atmosphere is strictly prohibited. It is mandatory to collect the refrigerant fl uid before carrying out any work on the circuit. •...