General Information; Introduction; Safety Requirements; Instrument And Manual Identification - Agilent Technologies E361 A Series Operating And Service Manual

Hide thumbs Also See for E361 A Series:
Table of Contents

Advertisement

GENERAL INFORMATION

INTRODUCTION

This manual describes all models in the Agilent E361xA 60W
Bench Power Supply family and unless stated otherwise, the
information in this manual applies to all models.

SAFETY REQUIREMENTS

This product is a Safety Class I instrument, which means
that it is provided with a protective earth ground terminal.
This terminal must be connected to an ac source that has a
3-wire ground receptacle. Review the instrument rear panel
and this manual for safety markings and instructions before
operating the instrument. Refer to the Safety Summary page
at the beginning of this manual for a summary of general
safety information. Specific safety information is located at
the appropriate places in this manual.
This power supply is designed to comply with the following
safety and EMC(Electromagnetic Compatibility) requirements
IEC 348: Safety Requirements for Electronic Measuring
Apparatus
IEC 1010-1/EN 61010: Safety Requirements for Electrical
Equipment for Measurement, Control, and Laboratory Use
CSA C22.2 No.231: Safety Requirements for Electrical and
Electronic Measuring and Test Equipment
UL 1244: Electrical and Electronic Measuring and Testing
Equipment.
EMC Directive 89/336/EEC: Council Directive entitled
Approximation of the Laws of the Member States relating to
Electromagnetic Compatibility
EN 55011(1991) Group 1, Class B/CISPR 11: Limits and
Methods of Radio Interference Characteristics of
Industrial, Scientific, and Medical(ISM) Radio-Frequency
Equipment
EN 50082-1(1991) /
IEC 801-2(1991): Electrostatic Discharge Requirements
IEC 801-3(1984): Radiated Electromagnetic Field
Requirements
IEC 801-4(1988): Electrical Fast Transient/Burst
Requirements
ICES/NMB-001
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Can-
ada.

INSTRUMENT AND MANUAL IDENTIFICATION

A serial number identifies your power supply. The serial
number encodes the country of manufacture, the date of the
latest significant design change, and a unique sequential
number. As an illustration, a serial number beginning with
KR306 denotes a power supply built in 1993 (3=1 993,
4=1994, etc), 6th week manufacture in Malaysia (MY). The
remaining digits of the serial number are a unique, five-digit
number assigned sequentially.
If a yellow Change Sheet is supplied with this manual, its pur-
pose is to explain any differences between your instrument
and the instrument described in this manual. The change
sheet may also contain information for correcting errors in
the manual.

OPTIONS

Options 0EM, 0E3 and 0E9 determine which line voltage is
selected at the factory. The standard unit is configured for 115
Vac ± 10%. For information about changing the line voltage
setting, see paragraph "INPUT POWER REQUIREMENTS",
page 1-6.
0EM:
Input power, 115 Vac ± 10%, 47-63 Hz
0E3:
Input power, 230 Vac ± 10%, 47-63 Hz
0E9:
Input power, 100 Vac ± 10%, 47-63 Hz
0L2:
One additional manual

ACCESSORY

The accessory listed below may be ordered from your local
Agilent Technologies Sales Office either with the power sup-
ply or separately. (Refer to the list at the rear of the manual for
address.)
Agilent Part No. Description
5063-9240
Rack Kit for mounting one or two 3 1/2" high
supply in a standard 19" rack
The rack mount kit is needed for rack mounting of all models
in the Agilent E361xA power supply because these supplies
have molded feet.

DESCRIPTION

This power supply is suitable for either bench or rack
mounted operation. It is a compact, well-regulated, Constant
Voltage/Constant Current supply that will furnish full rated
output voltage at the maximum rated output current or can be
continuously adjusted throughout the output range. The out-
put can be adjusted both locally from the front panel and
remotely by changing the settings of the rear panel switches
(See paragraph "REMOTE OPERATING MODES", page 1-9).
The models in this family offer up to 60 watts of output power,
with voltage up to 60 volts and current up to 6 amps as shown
in Table 1.
The front panel VOLTAGE control can be used to establish
the voltage limit when the supply is used as a constant cur-
rent source and the CURRENT control can be used to estab-
lish the output current limit when the supply is used as a
constant voltage source. The supply will automatically cross
over from constant voltage to constant current operation and
vice versa if the output current or voltage exceeds these pre-
set limits.
The front panel includes an autoranging (E3614A single-
range) digital voltmeter and a single-range digital ammeter.
Two 3 1/2 digit voltage and current displays accurately show
the output voltage and current respectively. The output rat-
ings for each model are shown in the Specifications and
Operating Characteristics Table.
The OVP/CC SET switch is used to check the OVP trip volt-
age and current control set value. When pressing this switch,
the voltage display indicates the OVP trip voltage and the cur-
rent display indicates the current control set value.
The power supply has both front and rear output terminals.
Either the positive or negative output terminal may be