Environmental Specifications; Connection Specifications; Table 3-6 Environmental Specifications; Table 3-7 Connection Specifications - Agilent Technologies U8030A Series User Manual

U8030a series triple output dc power supply
Table of Contents

Advertisement

3
Characteristics and Specifications

Environmental Specifications

Environmental Specifications

Table 3-6 Environmental specifications

Parameter
Operating temperature
Storage temperature
Humidity
Altitude
Fan acoustic noise
Environment of use

Connection Specifications

Table 3-7 Connection specifications

Parameter
Output connections
Binding posts
I/O connections
AC input
70
U8031A/U8032A
0 °C to 40 °C
–40 °C to 70 °C
15% RH (relative humidity) to 85% RH at 40 °C (non-condensing)
Up to 2000 meters
• No load: follow Agilent Class CO, 45 dB sound pressure and 50 dB sound
power
• Full load: follow Agilent Class GP, 55 dB sound pressure and 60 dB sound
power
• Installation Category II
• Pollution Degree 2
U8031A/U8032A
+Out, –Out, and chassis ground on the front panel.
(Either positive or negative output terminal may be grounded or can be operated floating at up to
a maximum of 240 V off ground. Total output voltage to ground must not exceed 240 V
Output binding post located horizontally and side by side
N/A
Three pins standard IEC AC power connector with fuse and line selection at
the rear
)
DC
U8030A Series User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U8031aU8032a

Table of Contents