Battery Precautions

• The batteries installed in the UPS and within the battery extensions may contain electrolyte.
Under normal conditions, the containers are dry. A damaged battery may leak electrolyte, which
can cause skin and eye irritation. Should this happen, wash the affected area with plenty of water
and seek immediate medical attention.
• Do not open or damage batteries. The released electrolyte is toxic.
• Voltage is always present on the battery contacts.
• Even when discharged, a battery has the capacity a high short circuit current which, in addition
to causing damage to the battery itself and associated cables, may expose the operator to the risk
of burns. The following precautions should be observed when working with batteries:
• Remove watches, rings and other metal objects.
• Use tools with insulated handles.
• The voltage of a single cell of a battery is not dangerous. However a number of cells or battery
blocks, connected in series, can produce hazardous voltages.
• The battery cabinet must not be kept in storage or not used for periods exceeding six months (at
20°C) without being recharged (having been charged to 100% at the beginning of any such period).
If this period is exceeded, it is essential that the batteries be recharged (which requires the UPS
to be switched On). If these conditions are not met, the battery performance can no longer be
guaranteed. We recommend recharging the batteries at least once every four months.
• Since new batteries often do not provide full capacity after the initial charge, it may be necessary
to carry out a number of discharge/recharge cycles before optimum performance is reached.
• When replacing batteries, replace with the same type and number of batteries and battery packs.
• In order to protect the environment, batteries must be disposed of in accordance with local laws
concerning the safe disposal of toxic and harmful waste.
• Do no not dispose of batteries in a fire. The batteries may explode.
3.13

Configuration Program

The final step of installation may require custom configuration of your UPS using the enclosed config-
uration program. Some configuration settings may be changed only while the UPS is Off. These
should be set before the UPS is put into full-time use.
For most users operating with 230VAC, the factory default settings will be adequate.
3.14

Liebert GXT3-10000T230 Configuration Program Features

• Select one of the three L-N output voltages to match local voltage.
• Enable/disable auto-restart.
• Select frequency converter operation with a fixed output frequency of 50 or 60 Hz.
• Set the 'Low battery warning' alarm time from 2 to 30 minutes.
• Enable/disable auto-battery test.
• Set auto-battery test frequency to 7, 14, 21 or 28 days.
• Specify the number of external battery cabinets connected to the UPS to adjust the remaining run
time calculations reported by the system software.
3.15

What You Will Need

In addition to the Liebert GXT3-10000T230, you will need the configuration program CD and USB
cable included in the UPS accessory pack. You must be running Microsoft
your computer.