Rear Vent Configuration Vented into Fireplace with Co-Linear Adapter

Attach the Co-Linear adapter directly to the back of the stove. Use UL 441 or 1775 gas liners to
vent the appliance through a code-conforming masonry or metal (zc) fireplace. All clearances to
combustibles must be met and the flex vent must be vented through a non-combustible fireplace
chimney.
Use the following components:
-- Travis Industries Rear Vent Conversion ( Part # 94400998)
-- Travis Co-Axial to Co-Linear Adapter (4" Exhaust, 3" Intake) (Part # 96200328)
-- Gas Insert Vent Kit "G" 3&4 (Part # 96200331)
- or -
3" and 4" Gas Liner and High Wind Cap (part # 46DVA-CL34) or equivalent
Vent height must be a minimum 10' and maximum 25'.
Exhaust Restrictor must be in Position #3 with the Exhaust Restrictor Extender Installed
Min. 18"
© Travis Industries
(for qualified installers only)
Approved Cap
Flashing and Adapter
3" (77mm) Dia. Intake
4" (102mm) Dia. Exhaust
Co-Axial to Co-Linear Adapter