Rear Vent Configuration With Horizontal Termination - Lopi GreenField GS2 Owner's Manual

Direct vent freestanding stove
Hide thumbs Also See for GreenField GS2:
Table of Contents

Advertisement

Rear Vent Configuration with Horizontal Termination

Use the rear vent conversion from Travis Industries (SKU 94400998).
Use 8" Diameter Vent
Horizontal sections require a ¼" (6mm) rise every 12" (305mm) of travel.
A maximum of three (3) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a
horizontal elbow (see illustration).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly, especially when the termination is near a demarcation line
Exhaust Restrictor Position #5
Exhaust Restrictor Extender Installed
12 feet max (3.6m)
10 feet (3m)
Exhaust Restrictor Position #3
Exhaust Restrictor Extender Installed
5 feet (1.5m)
© Travis Industries
Installation
0 feet
Horizontal elbows are elbows placed between
two horizontal sections of pipe. One 45° or 90°
horizontal elbow is allowed for this configuration.
(for qualified installers only)
Exhaust Restrictor Removed
Min. 1' (0.3m) Vertical Section Required
Horizontal Elbow
4121130
19
12 feet max (3.6m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01316

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenfield green smart 2

Table of Contents