3.5.7 UPS Configuration

Connect the UPS to the NVR's USB port for sending and receiving sig-
nals between the UPS and the NVR. The NVR can receive signal from
the UPS when there is a power failure and shut down itself automati-
cally within a period of time. You can enable UPS support to prevent
data loss when an unexpected power failure occurs.
To enable local UPS support (NVR acting as UPS server):
1. Connect the compatible USB UPS to the NVR
2. Turn on the NVR
3. Go to "NVR Setup" >> "System Options" >> "UPS Configurations",
and check "Enable UPS Support" option.
You can adjust how long the UPS stays on to provide backup electric-
ity to the NVR after a power failure by choosing one of the options
from the drop-down shown below:
* Currently only APC Smart-UPS 750 is supported (05282012)