Section 2: Circuit Requirements - Grizzly G0514 Owner's Manual

17" & 19" heavy duty bandsaws
Hide thumbs Also See for G0514:
Table of Contents

Advertisement

SEcTiON 2: ciRcUiT REQUiREMENTS

Serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. DO NOT connect
the machine to the power until instructed
later in this manual.
Electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. compliance MUST
be verified by a qualified
electrician!
NOTICE
The Model G0513/G0514 is prewired for
220V. if you plan to operate the machine at
110V, the motor must be rewired (see page
54) and a 110V plug must be installed.
full Load Amperage Draw
this machine draws the following amps under
maximum load:
amp draw at 220v (prewired) .............. 10 amps
amp draw at 110v ................................ 20 amps
power Supply circuit Requirements
the power supply circuit for your machine Must
be grounded and rated for the amperage given
below. never replace a circuit breaker on an exist-
ing circuit with one of higher amperage without
consulting a qualified electrician to ensure compli-
ance with wiring codes. if you are unsure about
the wiring codes in your area or you plan to
connect your machine to a shared circuit, con-
sult a qualified electrician.
Minimum Circuit size (220v) ................. 15 amps
Minimum Circuit size (110v) ..................30 amps
-12-
power connection Device
the type of plug required to connect your machine
to power depends on the type of service you cur-
rently have or plan to install. We recommend
using one of the plugs shown in figure 7.
L5-30 GROUNDED
LOCKING
RECEPTACLE
L5-30
LOCKING
PLUG
GROUNDED
6-15 RECEPTACLE
6-15 PLUG
figure 7. recommended plug types.
Extension cords
using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:
For 110v, use at least a 12 gauge cord that
does not exceed 50 feet in length.
For 220v, use at least a 14 gauge cord that
does not exceed 50 feet in length.
the extension cord must have a ground wire
and plug pin.
Model g0513/g0514 (Mfg. 8/02+)
l5-30 plug & outlet
for 110v
6-15 plug & outlet
for 220v