4. LEYEL/SYNC
M BLK: Master black level
The master black level can be set in the range from -128 to 127. When both UP and DOWN
are pressed together for 2 seconds, the value is set to zero.
R. BLK: R. black level
The R black level can be set in the range from-128 to 127. When both UP and DOWN
are pressed together for 2 seconds, the value is set to zero.
B. BLK: B black level
The B black level can be set in the range from-128 to 127. When both UP and DOWN
are pressed together for 2 seconds, the value is set to zero.
R. GAIN: R gain level
The R gain level can be set in the range frorn-128 to 127. When both UP and DOWN
are pressed together for 2 seconds, the value is set to zero.
However, the value is automatically set to zero in the WHT BAL:AUTO mode.
B. GAIN: B gain level
The B gain level can be set in the range from-128 to 127. When both UP and DOWN
are pressed together for 2 seconds, the value is set to zero.
However, the value is automatically set to zero in the WHT BAL:AUTO mode.
SYNC: The SYNC menu is executed.
RETURN: The MAIN MENU is displayed.
5. ADJUST
AUTO BLACK: The auto black balance function is executed by pressing the UP switch.
REMOTE: Setting of baud rate for remote control.
Note: Prior to setting the baud rate, connect the cable to the REMOTE connector.
62,500
Set to 62,500 bps when the dedicated remote control box like RC-C10 is used. In this case,
be sure to set the baud rate of the RC-C10 to 62,500 bps. For the baud rate setting of the RC-
C10, see the operation manual of the RC-C10.
2,400 bps, 4,800 bps, 9,600
Set to either of these baud rates when a PC is used.
For the PC control protocol and Data Command are needed please contact your nearest
Hitachi Denshi sales representative.
ID/TITLE: The ID/TITLE menu is executed.
RETURN: The MAIN MENU is displayed.