Draft Pipe Damper - Vogelzang International Sentry Coal VG810CL Owner's Manual

Coal stove
Hide thumbs Also See for Sentry Coal VG810CL:
Table of Contents

Advertisement

LOCATING STOVE continued...
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.
23"/
58.4cm
14"/
35.6cm
FLOOR PROTECTOR
Fig. 4a – Front View
CORNER
Minimum Clearance Dimensions
from Combustible Surfaces
CLEARANCES
18"/
45.7cm
18"/
45.7cm
Fig. 5 – Top View
Minimum Corner Clearances
from Combustible Surfaces
DRAFT DAMPER
A Draft Damper included with the stove must be
installed in the first straight section of pipe exiting the
stove before the stove pipe is connected and the wood
stove is used.
1. Drill two 1/4˝/6mm holes centered on either side of
the pipe section 6˝/15cm from the top end of the
pipe (figure. 6).
VGZ-011 / 20120105.0
NOTE: BEFORE FIRING STOVE SLIDE FIRE-
BRICKS TOWARDS THE REAR SO NO GAPS
REMAIN BETWEEN BRICKS.
18"/
45.7cm
18"/
45.7cm
28"/71.2cm
FLOOR PROTECTOR
Fig. 4b – Side View
Minimum Clearance Dimensions
from Combustible Surfaces
6"/15cm
Fig. 6 – Draft Damper Installation
VG810CL SENTRY COAL™ /
18"/
45.7cm
16"/
40.6cm
DRAFT DAMPER
(must be installed
before use — NO
EXCEPTIONS)
Continued on next page
Page 7