Heatilator EL36 Series Owner's Manual page 35

Wood burning fireplace installation and operation
Hide thumbs Also See for EL36 Series:
Table of Contents

Advertisement

TS345/TS345P Square Termination Cap
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).
Figure 9.7
Installing a TS345/TS345P Square Termination Cap
TCT375 Terra Cotta Cap
Remove 2 screws
from front & back
to lift the top off
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Termination cap pipe and chimney section must overlap
1-1/2 in. (38 mm)
Figure 9.8
Installing a TCT375 Terra Cotta Cap
Place waterproof sealer under
each flange of the termination
cap and on top of each screw
to help prevent leaks.
The last section of pipe must
stop between 2 in. (51 mm)
above the top of the chase and
4 3/4 in. (121 mm) below the
top of the chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
Chase
Place waterproof sealer
under each flange of the
termination cap and on
top of each screw to
help prevent leaks.
The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 7 in. (178 mm)
below top of chase
2 in. (51 mm)
7 in. (178 mm)
Chase
Pipe
Heatilator • EL36/EL42 • 4044-132 • Rev AC• 4/11
maximum
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

El42 series

Table of Contents